background image

Information

Indesit Company UK Ltd

© 2006 Reg. Office: Peterborough PE2 9JB. Registered in London: 106725

Service

Hotpoint

Ultima

Freestanding

Dishwashers

with Bit100

Electronics

Models Covered:-

FDW80
FDW85

Note:
Models produced after June 
2006 with DEA600 Electronics 
see Manual 5407345

5412771     Issue 2   Aug. 2006

Содержание ULTIMA FDW80

Страница 1: ...eterborough PE2 9JB Registered in London 106725 Service Hotpoint Ultima Freestanding Dishwashers with Bit100 Electronics Models Covered FDW80 FDW85 Note Models produced after June 2006 with DEA600 Ele...

Страница 2: ...ex equipment and the Company recommends that any problem with the appliance is referred to its own Service Organisation 8 Whilst the Company has endeavoured to ensure the accuracy of the data within t...

Страница 3: ...2 kW 230V Resistance 26 50 Circulation Motor Capacitor Run Induction Motor RPM 2800 Power Consumption 45 Watts Start Winding Resistance 67 Run Winding Resistance 94 Capacitor 5 uF Detergent Dispenser...

Страница 4: ...washed in either the upper or lower basket Drying is achieved with a fan and condenser system before Serial Number 50214 0000 Drying takes between 20 to 30 minutes depending on the programme selected...

Страница 5: ...0 14 0 17 0 1 7 0 14 36 18 44 1 8 4 4 20 60 36 71 45 89 4 5 8 9 MED 40 40 71 89 8 9 60 25 Water Hardness is adjusted by removing the salt container cap and turning the arrowhead adjuster towards the o...

Страница 6: ...s A wide range of wash cycles to choose from L Multifunction Numeric Indicator Informs of the duration of the cycle the amount of time left to wait and any error codes M Model Button Pressing this but...

Страница 7: ...shes Run cycle immediately after use Without drying except when the extra drying option has been selected Short wash at 40 C Hot rinse at 62 C 25 g with extra drying 25 Pre Wash Preliminary wash cycle...

Страница 8: ...s of fill water 217 impulses is equal to 1 litre of water The turbine also regulates the maximum amount of water that can enter the tub therefore acting as an overflow device If the turbine fills the...

Страница 9: ...ump housing It consists of a vane and a small motor and controls how the water is delivered to the spray arms The vane acts as a gate within the pump volute and is moved by the motor as required by th...

Страница 10: ...tay illuminated for the first 5 cycles after filling with salt On the 6th cycle the light will be extinguished The control module counts the activation of the regeneration valve and after the end of t...

Страница 11: ...water runs into the resin container to regenerate the resins The ionic exchange lasts between 20 25 minutes Two resin washes will then be performed 1 litre of water is filled This removes the salt wa...

Страница 12: ...24 Wash sump Rinse to 70 C 1 If the sensor contacts open for at least 5 secs after point 1 the rinse is repeated If the sensor contacts open during the 2nd rinse for at least 5 secs after point 1 the...

Страница 13: ...inse 10 mins Drain and fill 6 5 litres If the sensor contacts open for at least 5 secs after point 1 the rinse is repeated If the sensor contacts open during the 2nd rinse for at least 5 secs after po...

Страница 14: ...switch 2 litres filled via the TURBINE between rinses Motor pump ON Check pressure switch for 2 seconds Fill until pressure switch contacts close max 6 litres for 2 mins Pressure switch FILTER CLEANI...

Страница 15: ...n used for an extended period of time let the water run to make sure that the water is clear and free of impurities If this precaution is not taken there is a risk that the water inlet can get blocked...

Страница 16: ...2 Carefully tilt the machine backwards and lay the machine on its back 3 Remove the 3 screws securing the base panel at the front of the chassis 4 Disconnect the wiring to the float switch and remove...

Страница 17: ...ect the wiring to the pressure sensor 6 Disconnect the wiring to the motor multi pin connector 7 Remove the coiled motor fixing by levering of the end of the motor housing using a large flat blade scr...

Страница 18: ...1 Remove the right hand side panel as in D 2 Access can now be gained to the pressure switch mounted at the front of the chassis If the pressure hose is removed or replaced for any reason it is impor...

Страница 19: ...he tank See Figs 3 and 4 Tip the machine back slightly and slide the block supplied with the Special Tool Part Number 5600269 or similar support under the flat area of the sump Carefully lower the mac...

Страница 20: ...base pan Leak from water line AL 02 Solenoid valve broken Inlet valve letting by heater Earth fault open circuit heater AL 03 Time out draining Pump connections blockage module AL 04 Thermistor circu...

Страница 21: ...has been energised for 4 minutes but the pressure switch has not switched to the empty position contacts 11 12 The drain pump is fed from the wash pump therefore an open circuit wash pump could stop...

Страница 22: ...ing Replace module or display as required A10 Open circuit in heating circuit Check the circuit of the heating element 26 ohms Check for an open circuit heater cut out Check pressure switch open circu...

Страница 23: ...programme will be carried out 3 At the end of the test the buzzer sounds twice and END is displayed Pressing the P button will then enable the programmes to be selected as normal Short Test 1 Press t...

Страница 24: ...tted and will not come off the test cycle check 1 The correct card has been fitted The version is stamped on the label 2 Check for low resistance to Earth Test the wash pump and heater from their term...

Страница 25: ...X X X X Verify Pressure Switch Closed X X X X X X X Closed Fill 2 Litres via water turbine X X X X X X X Fill further 2 Litres if Pressure Switch is open maximum 2 minutes X X X X X X X 120 Closed Reg...

Страница 26: ...X X X X Verify Pressure Switch Closed X X X X X X Closed Fill 2 Litres via water turbine Circulate X X X X X X Fill further 2 Litres if Pressure Switch is open maximum 2 minutes X X X X X X 120 Closed...

Страница 27: ...VALVE CAPACITOR HEATER ALTERNATING WASH VALVE CIRCULATION MOTOR TURBIDITY SENSOR FLOAT SWITCH SAFETY SWITCH TEMPERATURE SENSOR HEATER RELAY WATER TURBINE WHITE RED RED BLUE LIGHT BLUE PINK CONTROL RI...

Страница 28: ...nd ACCESSORIES To order parts and accessories contact our National Mail Order Parts Hotline 08709 077 077 Monday to Friday 8 30am to 5 00pm Saturday 8 30am to 12 00 noon or online at www theservicecen...

Отзывы: