BEFORE YOU BEGIN

Read these instructions carefully and completely.

Ŷ

IMPORTANT

 – 

Save these instructions for 

local inspector’s use.

Ŷ

IMPORTANT

 – 

Observe all governing codes 

and ordinances.

Ŷ

Note to Installer – 

Be sure to leave these instructions 

with Consumer.

Ŷ

Note to Consumer – 

Keep these instructions for 

future reference.

Ŷ

Skill level

 – Installation of this appliance requires 

basic mechanical and electrical skills.

Ŷ 3URSHULQVWDOODWLRQLVWKHUHVSRQVLELOLW\RIWKHLQVWDOOHU
Ŷ 3URGXFWIDLOXUHGXHWRLPSURSHULQVWDOODWLRQLVQRW

FRYHUHGXQGHU:DUUDQW\

Subbase Installations

When installing a subbase to support the sleeve or an 

electrical receptacle for the power cord, the sleeve must 

project a minimum of 2 3/4 inches into the room to have room 

for the subbase and receptacle box. The sleeve must be 

installed between 3 1/4 to 5 1/2 inches (maximum) above floor 

(including carpeting).

IMPORTANT: 

If the sleeve projects more than 4 inches into a 

room, the maufacturer recommends that a subbase or leveling 

OHJVDFFHVVRU\DUHDGGHGWRSUHYHQWWKHVOHHYHIURPVDJJLQJ

or cantilevering into the room. 

Wall Preparation

3URSHUDWWHQWLRQWRZDOOSUHSDUDWLRQRSHQLQJVL]HDQGJRRG

contruction practices are essential to a trouble-free sleeve 

installation. 

Wall Opening Size: Recommended minimum wall 

opening is 42 1/4” wide by 16 1/8” high.

  

Wood/steel Framing: Build a frame to the minimum wall 

RSHQLQJVL]HWRVXSSRUWWKHVOHHYHDVVKRZQ

Framing and Minimum Wall Sleeve Opening

Header 4” x 4” or
(2) 2” x 4” on edge

Jack Stud

Cripple

Main Stud

Floor

Sub-Floor

Jack Stud

42 1/4”

16 1/8”

Masonry Walls:

 Create the recommended minimum wall 

RSHQLQJ´ZLGHE\´KLJK7KHVOHHYHZLOOQRW
VXSSRUWFRQFUHWHEORFNRUEULFNV8VHSURSHUVL]HGOLQWHOVWR

support block or bricks above wall opening. The sleeve should 

EHIDVWHQHGWRPDVRQU\ZDOOVZLWKPDVRQU\VFUHZVILHOG

supplied). If the opening is framed in wood, use wood screws 

to secure the sleeve. 

Curtain Walls:

 Use case angles to create the recommended 

PLQLPXPZDOORSHQLQJ´ZLGHE\´KLJKIRU

installations such as curtain walls, window walls, or where the 

structural material of the wall is insufficient to support or fasten 

the wall sleeve to. Case angles are pieces of steel or similar 

material that are formed to a 90° angle. Add holes to fasten the 

case angle to the sleeve and to the structural component of 

the wall Do not drill holes into the bottom of the sleeve. 

Introduction

These instructions cover the installation of the standard 

PHWDOZDOOVOHHYHWKURXJKPDVRQU\VWHHORUZRRGIUDPH

walls. Fasteners are field supplied. The air conditioner and 

UHDUJULOOHDUHVKLSSHGVHSDUDWHO\

The sleeve is shipped 

unassembled. It must be field assembled prior to installation. 

IMPORTANT:

 

DO NOT

 remove thermal insulation from 

sleeve. 

Packaged Contents

 
 
 
 
 
 
 
 

INSIDE
BOTTOM

Weather

Barrier

Top Panel
Right Side

Panel

Bottom

Panel

Left Side

Panel

Push Pins

A corrugated weather barrier is also included. If required, it 

FDQEHDWWDFKHGWRWKHUHDURIWKHVOHHYHWRSURYLGHWHPSRUDU\

weather protection.

Selecting Location

Use the following guide for selecting the proper sleeve 
location

7KHVOHHYHPD\EHLQVWDOOHGDJDLQVWWKHIORRULQFOXGLQJ

carpet), except for installations using subbase. See 

Subbase Installations

 section.

2.  For cord-connected air conditioner, an electrical receptacle 

must be located within reach of the power cord.

6WDQGDUG3RZHU&RUG/HQJWKLQPP

Voltage

/HIWRI6OHHYH

Right of Sleeve

230/208v

30 (762) 

70 (1778)

265v

&RQVXOWDLUFRQGLWLRQHUPDQXIDFWXUHU¶VVSHFLILFDWLRQVIRUDFWXDOSRZHUFRUG

length.

7KHYFRUGZLOOQRWH[WHQGEH\RQGERWWRPRIDLUFRQGLWLRQHU