Installation
Instructions

Gas Dryer

If you have any questions, call 1-800-GECARES (US) or 1-800-361-3400 (Canada)

or

 

Visit our Web site at:

 www. GEAppliances.com

BEFORE YOU BEGIN

TOOLS YOU WILL NEED

MATERIALS YOU WILL NEED

FOR YOUR SAFETY:

    WARNING

• Use only rigid metal or flexible metal 4-in. diameter
  ductwork for exhausting to the outdoors. Never use
  plastic or other combustible easy-to-puncture ductwork.
• This appliance must be properly grounded and installed
  as described in these instructions.
• Do not install or store appliance in an area where it
  will be exposed to water and/or weather.
• The National Fuel Gas Code restricts installations of
  gas appliances in garages. They must be 18 in. off the
  ground and protected by a barrier from vehicles.
• Install the dryer where the temperature is above 50ºF
  for satisfactory operation of the dryer control system. 

Read these instructions completely and carefully.

 IMPORTANT -

 Save these

    instructions for local inspector's use.

 IMPORTANT -

 Observe all

    governing codes and ordinances.

• Note to Installer 

- Be sure to leave these instructions with

  the customer. 

• Note to Customer - 

Keep these instructions with your Use

  and Care Book for future reference.
• This dryer must be exhausted to the outdoors.
• Before the old dryer is removed from service or discarded,

  remove the dryer door.

• Service Information and the wiring diagram are located in

  the control console. 

• D

• Service of this dryer must be performed by a qualified
  installer,service agency, or the gas supplier.

o not allow children on or in the appliance. Close

  supervision of children is necessary when the appliance is

  used near children.       

FLAT BLADE SCREWDRIVER

SLIP JOINT PLIERS

LEVEL

10" ADJUSTABLE WRENCHES (2)

8" PIPE WRENCH

SOAP SOLUTION

FOR LEAK DETECTION

DUCT TAPE

GLOVES

SAFETY GLASSES

DUCT
CLAMPS (2)

4" DIA. METAL ELBOW

4" DIA. METAL DUCT

(RECOMMENDED)

4" DIA. FLEXIBLE METAL DUCT

(IF NEEDED)

EXHAUST HOOD

PIPE COMPOUND

FLEXIBLE GAS LINE CONNECTOR

Step 1 Verify Your Gas Installation (see section 2).
Step 2 Prepare the Area and Exhaust for Installation of

New Dryer (see section 1).

Step 3 Check and Insure the Existing External Exhaust is

Clean (see section 1) and Meets Attached Installation
Specifications.(see section 6)

Step 4   Remove the Foam Shipping Pads (see section 1).
Step 5 Move the Dryer to the Desired Location.
Step 6 Level Your Dryer (see section 8).
Step 7 Connect the Gas Supply (see section 3) and check

for leaks (see section 4).

Step 8 Connect the External Exhaust (see section 7).
Step 9   Connect the Power Supply (see section 5).
Step 10  Check the Operation of the Power Supply, Gas

Connections, and Venting.

Step 11  Place the Owners Manual and the Installation

Instructions in a Location Where They Will Be
Noticed By the Owner.

     For Alcove or Closet Installation see section 9.
     For Bathroom or Bedroom Installation see section 10.
     For Mobile or Manufactured Home see section 11.

                     In the state of Massachusetts
Installation must be performed by a qualified or 
licensed contractor, plumber, or gasfitter qualified or
licensed by the state.

DESIGN

CERTIFIED

03

Содержание NBXR333GGWW - 6.0 cu. Ft. Gas Dryer

Страница 1: ...t be performed by a qualified installer service agency or the gas supplier o not allow children on or in the appliance Close supervision of children is necessary when the appliance is used near childr...

Страница 2: ...ed with a Valve Burner Assem bly for use only with natural gas Using conversion kit WE25X0217 your local service organization can convert this dryer for use with propane LP gas ALL CONVER SIONS MUST B...

Страница 3: ...nd fittings are designed for use only on the original installation and are not to be reused for another appliance or at another location Keep flare end of adaptor free of grease oil and thread sealant...

Страница 4: ...gid Metal Rigid Metal 90 Feet 60 Feet 45 Feet 35 Feet 0 1 2 3 55 Feet 40 Feet 30 Feet 60 Feet 45 Feet 35 Feet 20 Feet 25 Feet 45 Feet 30 Feet 20 Feet 15 Feet Flexible Metal Use only for short run inst...

Страница 5: ...EXHAUSTING IF SPACE IS LIMITED USE THE INSTRUCTIONS IN SECTION 12 TO EXHAUST DIRECTLY FROM THE LEFT SIDE OR BOTTOM OF THE CABINET WE RECOMMEND THAT YOU INSTALL YOUR DRYER BEFORE YOUR WASHER THIS WILL...

Страница 6: ...3 in front and rear Minimum vertical space from floor to overhead cabinets ceiling etc is 52 in Closet doors must be louvered or otherwise ventilated and must contain a minimum of 60 sq in of open are...

Страница 7: ......

Страница 8: ...PENING 14 SERVICING REMOVE 4 HINGE SCREWS ROTATE DOOR 180 AND REINSTALL REMOVE 4 HOLE PLUGS AND PLACE THEM IN THE HOLES ON THE OPPOSITE SIDE WARNING LABEL ALL WIRES PRIOR TO DISCONNECTION WHEN SERVICI...

Отзывы: