4
Do not let the burner flame extend beyond the edge of the pan.
Do not use : Cast iron griddles, ollar stones, terracotta pots and pans.
Heat diffusers such as metal mesh, or any other types. Two burners
simultaneously for one receptacle (e.g. Fish kettle).
Should particular local conditions of the delivered gas make the ignition
of burner difficult, it is advisable to repeat the operation with the knob
turned to small flame setting.
In case of installation of a hood above the cooktop, please refer to the
hood instructions for the correct distance.
The protective rubber feet on the grids represent a chocking hazard for
young children. After removing the grids, please ensure that all the feet
are correctly fitted.
INSTALLATION
The appliance must be handled and installed
by two or more persons - risk of injury. Use
protective gloves to unpack and install - risk of
cuts.
The electrical and gas connections must
comply with local regulations.
Installation, including water supply (if any),
electrical connections and repairs must be carried
out by a qualified technician. Do not repair or
replace any part of the appliance unless specifically
stated in the user manual. Keep children away from
the installation site. After unpacking the appliance,
make sure that it has not been damaged during
transport. In the event of problems, contact the
dealer or your nearest Aftersales Service. Once
installed, packaging waste (plastic, styrofoam
parts etc.)
must be stored out of reach of
children - risk of suffocation. The appliance must
be disconnected from the power supply before
any installation operation - risk of electric shock.
During installation, make sure the appliance does
not damage the power cable - risk of fire or electric
shock. Only activate the appliance when the
installation has been completed.
WARNING : Modification of the appliance and
its method of installation are essential in order to
use the appliance safely and correctly in all the
additional countries.
Use pressure regulators suitable for the gas
pressure indicated in the instructions.
The room must be equipped with an air
extraction system that expels any combustion
fumes.
The room must also allow proper air circulation,
as air is needed for combustion to occur normally.
The flow of air must not be less than 2 m³/h per
kW of installed power.
The air circulation system may take air directly
from the outside by means of a pipe with an inner
cross section of at least 100 cm²; the opening must
not be susceptible to blockages.
The system can also provide the air needed for
combustion indirectly, i.e. from adjacent rooms
fitted with air circulation tubes as described above.
However, these rooms must not be communal
rooms, bedrooms or rooms that may present a fire
hazard.
Liquid petroleum gas sinks to the floor as it
is heavier than air. Therefore, rooms containing
LPG cylinders must also be equipped with vents
to allow gas to escape in the event of a leak.
This means LPG cylinders, whether partially or
completely full, must not be installed or stored
in rooms or storage areas that are below ground
level (cellars, etc.). It is advisable to keep only the
cylinder being used in the room, positioned so
that it is not subject to heat produced by external
sources (ovens, fireplaces, stoves, etc. ) which
could raise the temperature of the cylinder above
50
°
C.
Should you find it difficult to turn the knobs for the burner, please
contact the After-sales Service, who can replace of the burner tap if
found to be faulty.
The openings use for the ventilation and dispersion of heat must never
be covered.
Do not remove the appliance from its
polystyrene foam base until the time of
installation.
Do not install the appliance behind a decorative
door - risk of fire.
GAS CONNECTION
WARNING : Prior to installation, ensure that the
local distribution conditions (type of gas and gas
pressure) and the configuration of the appliance
are compatible.
Check that the pressure of the gas supply is
consistent with the values indicated in Table 1
(“Burner and nozzle specifications”).
WARNING : The configuration conditions of
this appliance are stated on the label (or data
plate).
WARNING : This appliance is not connected
to a combustion products evacuation device. It
must be installed and connected in accordance
with current installation regulations. Particular
attention must be paid to the relevant
requirements regarding ventilation.
If the appliance is connected to liquid gas,
the regulation screw must be fastned as tightly as
possible.
IMPORTANT : When the gas cylinder or gas
container is installed, it must be properly settled
(vertical orientation).
WARNING : This operation must be perfomed
by a qualified technician
Use only flexible or rigid metal hose for gas
connection.
Connection with a rigid pipe (copper or steel)
Connection to the gas system must be carried
out in such a way as not to place any strain of
any kind on the appliance. There is an adjustable
L-shaped pipe fitting on the appliance supply
ramp and this is fitted with a seal in order to
prevent leaks. The seal must always be replaced
after rotating the pipe fitting (the seal is provided
with the appliance). The gas supply pipe fitting is
a threaded 1/2 gas cylindrical male attachment.