Mains frequency and voltage of the electric section and characteristics of the gas section
Model
Gas section
Class
Rated power
kW (1)
II2H3+
8,00 (582 g/h - G30)
( g/h - G31)
(1) The values in g/h refer to the capacities with liquid gas (Butane, Propane).
* At 15°C and 1013 mbar - dry gas
** Propane P.C.S. = 50,37 MJ/Kg
*** Butane P.C.S. = 49,47 MJ/Kg
Natural P. C.S. = 37,78 MJ/m3
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
GAS NOZZLE TABLE
12
HDM67G8C2CX/UK
571
EN
Table 1
Liquid Gas Natural Gas
Burner
Diameter
(mm)
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
By-Pass
1/100
(mm)
Nozzle
1/100
(mm)
Flow*
g/h
***
**
Thermal Power
kW (p.c.s.*)
Nominal
Reduced
Nozzle
1/100
(mm)
Flow*
l/h
Triple Crown
(TC)
130
3.3 1.50
63
2x65
236
232
3.3 1.50
2x99
309
Semi Fast
(Medium)(S)
75
2.0
0.4
30
69
145
143
2.0 0.4
104
190
Auxiliary
(Small)(A)
55
1.0
0.4
30
50
73
71
1.0
0.4
78
95
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30 37
20
25
35
45
20
17
25
Table 1
Liquid Gas Natural Gas
Table 1
Liquid Gas Natural Gas
)
The front right hob burner injector should be used as the pressure test point.