to “regulators for channelled gas”.
Burner and Nozzle
Specification
*
At 15°C and 1013 mbar- dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane P.C.S. = 49,47 MJ/Kg
Natural P.C.S. = 37,78 MJ/m
3
S
S
R
A
Table 1
Liquid Gas
Natural Gas
Burner
Diameter
Thermal Power
kW (p.c.s.*)
By-Pass
1/100
Nozzle
1/100
Flow*
g/h
Nozzle
1/100
Flow*
l/h
(mm)
Nominal
Reduced
(mm)
(mm)
***
**
(mm)
Fast
(Large)(R)
100
94
2,60
0,7
41
80
189
186
118
286
Semi Fast
(Medium)(S)
75
69
1,90
0,4
30
70
138
136
104
181
Auxiliary
(Small)(A)
51
46
1,00
0,4
30
52
73
71
76
95
Oven
-
2,60
0,6
36
71
189
186
115
248
Grill
-
2,50
1,3
63
80
182
179
122
238
Supply
Pressures
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
28-30
20
35
37
25
45
20
17
25
HAGL 51 P
HAGL 51 K