Hotpoint FF187EA Скачать руководство пользователя страница 1

Indesit Company UK Ltd

© 2009 Reg. Office: Peterborough PE2 9JB Registered in London: 106725

Service

 

Information

HOTPOINT

Freestanding 

Frost Free 

Fridge Freezers

(Version 2)

Refer to Insert below

Models

Comm.

Covered

Code

FF187EA

40729

FF187EG

39780

FF187EK

53950

FF187EP

39775

FF187EPL

53947

FF200EA

40733

FF200EG

40732

FF200EX

43503

FF200EK

53952

FF200EP

39777

FF200EPL

53949

IMPORTANT

THERE ARE TWO VERSIONS OF THE 
ABOVE LISTED MODELS. TO IDENTIFY THE 
CORRECT VERSION AND SERVICE 
MANUAL SEE BELOW OR Page 5 FOR A 
MORE DETAILED EXPLANATION:

VERSION 1 ~

 

THE POWER MODULE IS MOUNTED AT THE 
REAR OF THE APPLIANCE ABOVE THE 
COMPRESSOR COMPARTMENT.

VERSION 2

 ~

THE POWER MODULE IS MOUNTED IN THE 
CONTROL PANEL ONLY, THERE IS NO 
REAR MOUNTED MODULE.

FOR VERSION 1 MODELS 

~ REFER TO 

SERVICE MANUAL 5407327

  5407423  Issue 1     Feb. 2009

Содержание FF187EA

Страница 1: ...0EG 40732 FF200EX 43503 FF200EK 53952 FF200EP 39777 FF200EPL 53949 IMPORTANT THERE ARE TWO VERSIONS OF THE ABOVE LISTED MODELS TO IDENTIFY THE CORRECT VERSION AND SERVICE MANUAL SEE BELOW OR Page 5 FO...

Страница 2: ...cordless power tools are forbidden within the storage area working area and vehicles used to transport Isobutane 9 The carrying case for the scales and refrigerant must display a red flammability lab...

Страница 3: ...damage and heat The aluminium case must NEVER be placed next to a heat source or in direct sunlight 3 Isobutane must only be dispensed to the appliance from the 1kg net aluminium canister placed in an...

Страница 4: ...sor Information 34 Door Reversal Instructions 35 PRODUCT IDENTITY Mod TI Cod 93139180000 S N 704211801 220 240 V 50 Hz 150 W W Fuse A Max 15 w Total Gross Bruto Brut Compr Kompr Syst R 134 a kg 0 090...

Страница 5: ...power module to positively identify the model version See version descriptions and photos below VERSION 1 Refer to Service Manual 5407327 C00221355 See photo below Models produced on or before serial...

Страница 6: ...the lower right side of the freezer cabinet liner 3 Freezer Evaporator Sensor inserted into the top right of the evaporator The sensors thermistors are not replaceable because they are for the most p...

Страница 7: ...Frost Fin On Tube FOT Evaporator DIMENSIONS WEIGHT Models FF187E FF200E Height 1870 mm 2000 mm Width 600 mm 600 mm Depth 655 mm 655 mm Weight Gross 67 4 kg 78 0 kg Weight Net 64 5 kg 67 4 kg CAPACITIE...

Страница 8: ...bed Current 0 5 A COMPRESSOR WINDINGS FF187E FF200E Manufacturer Jiaxipera Tecumseh Type I D ZBT1114CY TWB1370MJS Winding Resistances Start 16 0 26 75 R un 13 3 15 75 Refrigerant Type Grams R600a Refe...

Страница 9: ...lable only on certain models Removable lidded shelf with EGG TRAY Removable multipurpose SHELF BOTTLE shelf Control panel FRESH BOX Compartment FF200E models only FREEZER and STORAGE compartment STORA...

Страница 10: ...onserve make up and beauty products The FREEZER OPERATION knob MUST be set to MIN in order to preserve the frozen food An acoustic signal sounds when this function is enabled or disabled The SUPER FRE...

Страница 11: ...fridge or freezer sensors failing Pre set timed functions stored in the module memory are used to cycle cold request on and off A malfunction occurs when the fridge or freezer cabinet sensors return...

Страница 12: ...in the presence of a cooling demand 3 Pause after defrost at the end of the defrost cycle the compressor observes a protection time parameterised in the module memory so that the water formed during t...

Страница 13: ...uper Freeze button in until all three LED lights illuminate at the same time The LED lights will extinguish after 5 seconds Automatically After 300 seconds from start of the Auto Test it will be deact...

Страница 14: ...or explanations Super Cool Mains Super Freeze Audible Bleep Amber Green Amber OFF FLASHING OFF NO F 01 ON FLASHING OFF NO F 02 OFF FLASHING ON NO F 03 ON FLASHING ON NO F 04 FLASHING FLASHING ON NO F...

Страница 15: ...ions thermal cut out open Replace power module Replace compressor F 03 Faulty Power Module Replace power module F 04 Evaporator Fan Motor Not Running Check module connector E1 Check resistance reading...

Страница 16: ...inate Check module connector E1 Check resistance reading between pins 3 and 4 of connector E1 Replace lamps Replace power module F 21 NTC ambient sensor on power module faulty Replace power module F 2...

Страница 17: ...it Check module connector E4 Check NTC sensor ensuring that the values read between pins 1 and 2 of connector E4 is compatible with the values in the Sensor Resistance Table on page 34 also heat the s...

Страница 18: ...THE FREEZER COMPARTMENT IS DRAWN BACK UNDER THE REAR DUCT PANELTO THE EVAPORATOR ASSEMBLY AIR FLOW RETURNS TO THE FRIDGE VIA THE INLET DUCTING NOTE THE DAMPER BAFFLE IN THE FRIDGE MULTI FLOW UNIT NEED...

Страница 19: ...EVAPORATOR FAN DRAWS AIR UNDER AND BEHIND THE REAR DUCT PANEL AND THROUGH THE EVAPORATOR ASSEMBLY IT IS THEN BLOWN BETWEEN THE FRONT AND REAR DUCT PANELS AIR FLOW IS THEN CHANNELLED AND DISTRIBUTED UN...

Страница 20: ...t sequence will be initiated Compressor Operation There are situations of cooling demand in which the compressor remains off These are as follows Compressor protection the compressor switches on once...

Страница 21: ...heater is ON 32 minutes Defrost end temperature freezer evaporator sensor 10 C Freezer Fan Operation The freezer fan is managed by the power module and is switched on off after a preset time interval...

Страница 22: ...d by foam then remove where possible FREEZER EVAPORATOR FAN NOT RUNNING The fan is managed by the power module and is switched ON OFF after a pre set time interval that is parameterised in the module...

Страница 23: ...or PTC faulty Compressor Start or Run windings faulty Check the resistances of the compressor windings Refer to Diagnostic Manual 5407355 for further testing of the compressor There are situations of...

Страница 24: ...and wiring harness 5 Release the wiring from the module D POWER CONTROL Module NOTE Assemble in the same order starting at position A then B aligning the control knobs to the potentiometers mounted o...

Страница 25: ...t as in G1 to G5 2 Disconnect baffle wiring from the terminal block above the baffle unit To release the plug depress the tab on its upper side 3 Replace seals as necessary to ensure good sealing K Fr...

Страница 26: ...OTE The previous low end adaptor can be identified with Version 2005 printed on the plastic housing Version 2005 adaptors must not be connected to New Platform modules There are two different methods...

Страница 27: ...ure the correct Hardware key is selected Black 9 Ensure the correct Appliance type is selected New Platform 10 Open Com Port A bright green connection icon will light on screen 11 Select Part No or Co...

Страница 28: ...Adaptor See photo 5 5 Connect the appliance to the Electrical supply The LED s on the Smart Card Reader will light in this sequence a Red ON Good Communication between Smart Card Reader Card See also...

Страница 29: ...NNECT unplug THE APPLIANCE FROM THE ELECTRICAL SUPPLY grid DOWNLOAD OK THE SMARTCARD CONTENT WILL BE AUTOMATICALLY ERASED IF THE RED LED IS STATIC fixed x DOWNLOAD HAS FAILED KO IF THE DOWNLOAD FAILED...

Страница 30: ...event damage to the harness of the adaptor key route it under the screw fixing post of the control panel NOTE Unplug the appliance from the mains supply before disconnecting the adaptor key The origin...

Страница 31: ...SIDE ALTERNATIVE DEFROST HEATER AND THERMAL FUSE CONNECTION PLUG REAR VIEW WIRE SIDE THERMAL FUSE CLIPPED TO EVAPORATOR DEFROST HEATER AND THERMAL FUSE CONNECTION SOCKET ALTERNATIVE CONNECTION SOCKET...

Страница 32: ...AL No WIRE COLOUR COMPONENT 6 NOT USED 5 NOT USED 4 BLACK FRIDGE DAMPER BAFFLE 3 GREY FRIDGE DAMPER BAFFLE 2 RED FRIDGE DAMPER BAFFLE 1 WHITE FRIDGE DAMPER BAFFLE E 4 IDC CONNECTIONS TERMINAL No WIRE...

Страница 33: ...OR FAN MOTOR FRIDGE DAMPER baffle FRIDGE INTERIOR LAMP THERMAL FUSE THERMAL FUSE COMPRESSOR OVERLOAD CAPACITOR if fitted EVAPORATOR DEFROST HEATER GUTTER HEATER FLY LEAD HARNESS TO COMPRESSOR COMPARTM...

Страница 34: ...ep behind the duct mounting on the right 2 Freezer Evaporator Sensor Located in the top right corner of the freezer evaporator 3 Fridge Air Sensor Located in the return duct behind the fridge multi fl...

Страница 35: ...e fixing plate transfer them both to the left hand side The hinge pin also needs to be transferred to the left pre threaded hole Fig 3 Before the plinth is screwed back in place cut out the pre marked...

Страница 36: ...36 of 36 Indesit Company Service Manual UK English...