Prior to installation, ensure that the local distribution
conditions (nature of the gas and gas pressure) and
the adjustment conditions are compatible. The
adjustment conditions for this appliance are stated
on the data badge which is fitted on the back panel.
This appliance is not designed to be connected to a
combustion products evacuation device. It must be
installed and connected in accordance with current
installation regulations. particular attention should be
given to the relevant requirements regarding
ventilation.
MODE
L
N
U
MBERS EG1000GX and
EG1000EX
Category II2H3
+
(GB)
These models are set to burn NATURAL GAS (G20)
at 20 mbar but can be converted for use on BUTANE
(G30) at 28-30mbar or PROPANE (G31) at 37mbar
with the use of the LPG conversion kit that can be
obtained free of charge, if you contact our Genuine
Parts and Accessories department (see back page).
G
A
S S
A
FETY (INST
ALLA
TION &
U
SE)
REG
ULA
TIONS
It is the law that all gas appliances are installed by
competent persons in accordance with the current
edition of the above regulations. It is in your interest
and that of safety to ensure compliance with the law.
In the UK, CORGI registered installers work to safe
standards of practice. The cooker must also be
installed in accordance with BS 6172. Failure to
install the cooker correctly could invalidate the
warranty liability claims and could lead to
prosecution.
I
ns
t
alla
t
ion
L
O
C
A
T
I
O
N
The cooker may be located in a kitchen, kitchen/
diner or a bed-sitting room, but not in a room
containing a bath or shower. The cooker must not be
installed in a bed-sitting room of less than 20m
3
.
When adjusted for use on Butane (G30) or Propane
(G31), the cooker must not be installed in a room or
internal space below ground level, e.g. in a
basement.
P
RO
V
ISION FOR
V
ENTI
LA
TION
The room containing the cooker should have an air
supply in accordance with BS 5440: Part 2.
The room must have an opening window or
equivalent; some rooms may also require a
permanent vent. If the room has a volume between 5
and 10m
3
, it will require an air vent of 50cm
2
effective area unless it has a door which opens
directly to outside. If the room has a volume of less
than 5m
3
, it will require an air vent of 100cm
2
effective area. If there are other fuel burning
appliances in the same room, BS 5440: Part 2
should be consulted to determine air vent
requirements.
TECHNIC
AL
D
A
T
A
DIMENSIONS
Height
900 - 915 mm
Widht
1000 mm
Depth
600 mm
(excluding door handles)
GENER
AL
Gas connection
Rp
½
(
½
" BSP female)
Pressure test point
Hotplate burner injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
230-240V~ 50Hz.
Total electrical heat input 6.00-6.80 kW (EG1000GX)
7.80-8.70 kW (EG1000EX)