Prior to installation, ensure that the local distribution conditions (nature of the gas and gas pressure) and the
adjustment conditions are compatible. The adjustment conditions for this appliance are stated on the data badge
which is fitted on the back panel. This appliance is not designed to be connected to a combustion products
evacuation device. It must be installed and connected in accordance with current installation regulations. particular
attention should be given to the relevant requirements regarding ventilation.
MODEL NUMBERS CH60GPCF; CH60GPXF
Category II2H3+ (GB)
These models are set to burn NATURAL GAS (G20) at 20 mbar but can be converted for use on BUTANE (G30) at
28-30mbar or PROPANE (G31) at 37mbar with the use of the LPG conversion kit that can be obtained free of charge,
if you contact our Genuine Parts and Accessories department (see Key Contacts, back page).
GAS SAFETY (INSTALLATION & USE) REGULATIONS
It is the law that all gas appliances are installed by competent persons in accordance with the current edition of the
above regulations. It is in your interest and that of safety to ensure compliance with the law.
In the UK, Gas Safe registered installers work to safe standards of practice. The cooker must also be installed in
accordance with BS 6172. Failure to install the cooker correctly could invalidate the warranty liability claims and
could lead to prosecution.
LOCATION
The cooker may be located in a kitchen, kitchen/diner or a bed-sitting room, but not in a room containing a bath or
shower. The cooker must not be installed in a bed-sitting room of less than 20m
3
.
When adjusted for use on Butane (G30) or Propane (G31), the cooker must not be installed in a room or internal
space below ground level, e.g. in a basement.
PROVISION FOR VENTILATION
The room containing the cooker should have an air supply in accordance with BS 5440: Part 2.
The room must have an opening window or equivalent; some rooms may also require a permanent vent. If the room
has a volume between 5 and 10m
3
, it will require an air vent of 50cm
2
effective area unless it has a door which opens
directly to outside. If the room has a volume of less than 5m
3
, it will require an air vent of 100cm
2
effective area. If
there are other fuel burning appliances in the same room, BS 5440: Part 2 should be consulted to determine air vent
requirements.
TECHNICAL DATA
Gas connection
Rp ½ (½” BSP female)
Pressure test point
Front left hotplate injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
Flexible cord fitted with a 3 pin 13 amp plug
230/240V
a.c.
50Hz.
13A
fuse.
INSTALLATION INSTRUCTIONS
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
HEAT INPUT
INJECTOR
HEAT INPUT
INJECTOR
HOTPLATE
Front Left
4.1 kW
100 + 72 + 100
3.8 kW (275g/h)
63 + 42 + 63
HOTPLATE
Rear Right
3.05 kW
116
3.0 kW (220g/h)
86
HOTPLATE
Rear Right and Rear Left
2.0 kW
103
2.0 kW (145g/h)
70
Grill
3.7 kW
150 (X)
3.4 kW (245g/h)
91
Main Oven
2.5 kW
115
2.3 kW (165g/h)
71
Top Oven
1.9 kW
100
1.9 kW (135g/h)
66