TECHNICAL DATA
Gas connection
Rp
1
/
2
(
1
/
2
" BSP female)
Pressure test point
Front left hotplate injector
Gas rate adjustment
None
Aeration adjustment
None
Electrical connection
Flexible cord fitted with a 3 pin 13 amp plug
230/240V a.c. 50Hz. 13A fuse.
HEAT
INPUT
G20 at 20mbar
G30 at 28-30mbar
G31 at 37mbar
BURNER
INJECTOR
3.7 kW
GRILL
150
2.5 kW
MAIN OVEN
115
1.9 kW
TOP OVEN
100
3.0 kW
HOTPLATE
Front left and rear right
116
2.0 kW
HOTPLATE
Front right and rear left
103
HEAT
INPUT
INJECTOR
3.4 kW (245g/h)
92
2.3 kW (165g/h)
72
1.9 kW (135g/h)
65
3.0 kW (220g/h)
86
2.0 kW (145g/h)
70
24
Installation
Содержание 61DGW Instructions for and use
Страница 31: ......