background image

 

 

15

 

 

      

HH468SE 25-07-12 

 

 

 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Hothouse Inspired Products Ltd 

Imperial Point 

Express Trading Estate 

Stonehill road 

Farnworth 

Bolton BL4 9TN 

 

Tel:

  

01204 - 862286

              

Fax:

  

01204 - 868569

 

 

The Clean Air Act 1993 and Smoke Control Areas

 

 
Under the Clean Air Act local authorities may declare the whole or part of the district of the

 

authority to be a smoke control area. It is an offence to emit smoke from a chimney of a

 

building, from a furnace or from any fixed boiler if located in a designated smoke control area.

 

It is also an offence to acquire an "unauthorised fuel" for use within a smoke control area

 

unless it is used in an "exempt" appliance ("exempted" from the controls which generally

 

apply in the smoke control area). 

 

The Secretary of State for Environment, Food and Rural Affairs has powers under the Act to

 

authorise smokeless fuels or exempt appliances for use in smoke control areas in England. In

 

Scotland and Wales this power rests with Ministers in the devolved administrations for those

 

countries. Separate legislation, the Clean Air (Northern Ireland) Order 1981, applies in Northern

 

Ireland. Therefore it is a requirement that fuels burnt or obtained for use in smoke control

 

areas have been "authorised" in Regulations and that appliances used to burn solid fuel in

 

those areas (other than "authorised" fuels) have been exempted by an Order made and signed

 

by the Secretary of State or Minister in the devolved administrations.

 

Further information on the requirements of the Clean Air Act can be found here :

 

http://smokecontrol.defra.gov.uk/ 

 

Your local authority is responsible for implementing the Clean Air Act 1993 including

 

designation and supervision of smoke control areas and you can contact them for details of

 

Clean Air Act requirements

 

Содержание HH4SE

Страница 1: ... uk PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY For safety reasons it is essential that your stove is correctly installed and operated Hothouse cannot accept responsibility for any fault or consequential problems arising through incorrect installation or operation The HH4SE HH6SE and HH8SE have been exempted under the clean air act 1993 as suitable for use in smoke control areas when burning seas...

Страница 2: ...Connection to Chimney 4 Material Clearances 5 Hearths 5 Commissioning Handover 5 5 Technical Data 6 6 Operating Instructions 6 Air controls 6 Cleaning 7 Fuels 7 Notes on Wood Burning 7 Lighting the stove 8 Re fuelling 8 Shutting down 8 Maintenance 8 Seasonal Use 8 7 Safety Notes for your Guidance 8 8 Stove Dimensions 10 9 Frequently Asked Questions 11 10 HH 4SE Spare Parts List Codes 12 11 HH 6SE ...

Страница 3: ...tove assembly and controls Fig 2 HH4SE Stove Assembly and controls Description of Parts Qty Hothouse Stove Assembly 1 Tool 1 Ash Pan 1 Flue Collar 1 Flue Collar fixing screws Washers 4 Legs 4 Stove Operating Glove 1 Touch up paint 1 Warranty Card 1 Fig 1 Stove Tool ...

Страница 4: ... referred to as they affect the installation of the stove Approved Document J is particularly important for England and Wales and can be downloaded for no cost at http www planningportal gov uk england professionals en 4000000000503 html Also of importance are Approved documents L1 A and B conservation of fuel and power The Domestic Heating Compliance Guide will also be found useful Important Chim...

Страница 5: ... the chimney should be lined by a suitable method The chimney must be swept before connection to the stove Where the chimney is believed to have previously served an open fire installation it is possible that the higher flue gas temperature from the stove may loosen deposits that were previously firmly adhered with the consequent risk of flue blockage It is therefore recommended that the chimney b...

Страница 6: ...onditions downdrafts may occur causing smoke or fumes to spill into the room If this occurs the appliance should be shut down as much as possible by closing the air controls and the room should be ventilated to clear the fumes If the problem persists seek the advice of a chimney sweep Material Clearances Safety Distances from Combustible Surfaces Model Side Rear HH4SE 500mm 700mm HH6SE 400mm 400mm...

Страница 7: ...nly the recommended fuels for the stove Advise the user on what to do should smoke or fumes be emitted into the room from the stove see Safety Notes section The user should be warned that they MUST use a suitable fireguard in the presence of children aged and or infirm persons 5 0 Technical Data Technical Specifications Wood HH4SE HH6SE HH8SE Nominal Heat Output kW 4 2 6 1 7 5 Efficiency 76 6 81 7...

Страница 8: ...ure that the primary airflow is not impeded as a build up of ash can damage the cast iron bed Ashpan It is essential that you empty the steel ash pan every day Use the thick end of tool to hook onto and lift the ash pan out of the stove DO NOT allow ash to build up underneath the bed as this may cause damage to the grate Cleaning Glass Despite the advanced air wash system provided the glass will s...

Страница 9: ... smell whilst the finishes finally cure It is non toxic but for your comfort we would suggest that during this period you leave all doors and windows open First open the primary and secondary air wash control fully Load the firebox with plenty of starting fuel i e paper dry sticks and or firelighters Light the fire at the base leaving the primary and secondary air control fully open Leave the door...

Страница 10: ...ue ways and ensure they are 100 clear after a period of disuse e g summer Only use manufacturers recommended replacement parts on the appliance Seasonal Use Remove the baffle and inspect the inside of the stove and the flue ways and ensure they are 100 clear after a period of disuse for example if the stove is not used during the warmer periods of the year Also set the air controls to 50 to keep t...

Страница 11: ...nearby ornaments Place a fireguard or spark guard in front of the stove Feel the chimneybreast for sign of excessive heat If the wall is becoming hot move the furniture away Ensure that the Fire Brigade can gain access to your roof space in order to check this area for signs of fire spread 8 0 Stove Dimensions Fig 3 HH 4SE 6SE 8SE Stove Stove A B C D E F G H J HH4SE 396 535 382 290 60 397 115 5 26...

Страница 12: ...r attends any stove problem that is not related to product failure 6 Where can I get spare parts Your local Hothouse Stove retailer will be pleased to supply spare parts and to provide any other information you require 7 Can the doors be left open while burning For safety and heat efficiency the doors should remain closed 8 Why is the stove smoking when lit A flue with back draught problems is alm...

Страница 13: ...ireboard Y1HDF04D06E 28 Front Y1HDF04D34E 07 Side Plate Right fireboard Y1HDF04D07E 29 Base Y1HDF04D35E 08 Riddle Grate Y1HDD08E 30 Side Right Y1HDF04D36E 09 Grate for Riddle Grate Y1HDF04D12E 31 Side Left Y1HDF04D37E 12 Riddle Grate Handle Y1HHF04D15E 32 Top Y1HHF04D38E 13 Riddle Grate Bar Y1HDF04D16E 33 Blanking plate Y1HDF39E 16 Baffle Plate Y1HDF04D19E 34 Back Y1HDF04D41E 18 Airwash slider pla...

Страница 14: ...e Plate Right fireboard Y1HDF06D07E 28 Front Y1HDF06D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF06D35E 09 Grate for Riddle Grate Y1HDF06D12E 30 Side Right Y1HDF06D36E 10 Grate Mounting Bracket Left Y1HDF06D13E 31 Side Left Y1HDF06D37E 11 Grate Mounting Bracket Right Y1HDF06D14E 32 Top Y1HHF06D38E 12 Riddle Grate Handle Y1HHF06D15E 33 Blanking plate Y1HDF39E 13 Riddle Grate Bar Y1HDF06D16E 34 Back Y...

Страница 15: ...e Plate Right fireboard Y1HDF08D07E 28 Front Y1HDF08D34E 08 Riddle Grate Y1HDD09E 29 Base Y1HDF08D35E 09 Grate for Riddle Grate Y1HDF08D12E 30 Side Right Y1HDF08D36E 10 Grate Mounting Bracket Left Y1HDF08D13E 31 Side Left Y1HDF08D37E 11 Grate Mounting Bracket Right Y1HDF08D14E 32 Top Y1HHF08D38E 12 Riddle Grate Handle Y1HHF06X15E 33 Blanking plate Y1HDF40E 13 Riddle Grate Bar Y1HDF08X16E 34 Back Y...

Страница 16: ...has powers under the Act to authorise smokeless fuels or exempt appliances for use in smoke control areas in England In Scotland and Wales this power rests with Ministers in the devolved administrations for those countries Separate legislation the Clean Air Northern Ireland Order 1981 applies in Northern Ireland Therefore it is a requirement that fuels burnt or obtained for use in smoke control ar...