17
10. Startup
IMPORTANT
1. The condensing unit is shipped with the contacts of the secondary low
pressure switch open. Once power is supplied to the condensing unit, wait at
least 4 hours before starting the unit.
This will allow the system to settle and
refrigerant to evaporate from oil in the compressor. To start the unit, press the
manual reset button on the secondary low pressure switch. Doing this will
prevent damage to the compressor.
2. If the unit is turned off, wait for at least 3 minutes before restarting the
icemaker to prevent damage to the evaporator.
3. In the event of a power failure that is less than 3 minutes in duration, the gear
motor fuse in the ice machine could blow upon restart. If this occurs, turn off
the machine, replace the fuse and wait at least 3 minutes before restarting.
1) Clean the storage bin. (See “III. 2. Maintenance Instructions.”)
2) Open the water supply line shut-off valve.
3) Move the flush switch on the control box to the “ICE” position.
4) Turn on the power switch on the control box.
5) Replace all exterior panels in their correct positions.
6) Turn on the power supply.