38
Freeze Timer (9 & 10)
Pump-Out Frequency Control (5)
Pump-Out Time/Harvest Time During Pump-Out (3 & 4)
Harvest Timer (1 & 2)
Factory Use (8)
Harvest Pump Time (Harvest Assist)/Freeze-Time Correction
(7) (Do Not Adjust)
1
2
3
4
5
6
7
8
9
10
ON
S4 Dip Switch
Harvest Pump Time (Harvest Assist Duration) (6) (Do Not Adjust)
1
2
3
4
5
ON
Do Not Adjust
S5 Dip Switch
Refill Counter (2 and 3)
Float Switch Selector (1)
Minimum Harvest Time (4)
Anti-Slush (5)
C. Settings and Adjustments
NOTICE
Dip switches are factory set. Failure to maintain factory settings may adversely
affect performance and warranty coverage. For more information, contact Hoshizaki
Technical Support at 1-800-233-1940.
1. Default Dip Switch Settings
The dip switches are factory-adjusted to the following positions:
S4 Dip Switch
Dip Switch No.
1
2
3
4
5
6
7
8
9
10
KMS-2000MLJ OFF OFF OFF OFF OFF OFF ON OFF OFF OFF
S5 Dip Switch (Do Not Adjust)
Dip Switch No.
1
2
3
4
5
KMS-2000MLJ OFF OFF OFF OFF OFF