![Hoshizaki Serenity KMS-2000MLJ Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/hoshizaki/serenity-kms-2000mlj/serenity-kms-2000mlj_service-manual_2164866013.webp)
13
B. Service Diagnosis
WARNING
• The appliance should be diagnosed and repaired only by qualified service
personnel to reduce the risk of death, electric shock, serious injury, or fire.
• Risk of electric shock. Control switch in "OFF" position does not de-energize all
loads. Use extreme caution and exercise safe electrical practices.
• Moving parts (e.g., fan blade) can crush and cut. Keep hands clear.
• Before servicing the appliance, move the control switch to the "OFF" position and
turn off the power supply.
•
CHOKING HAZARD:
Ensure all components, fasteners, and thumbscrews are
securely in place after the appliance is serviced. Make sure that none have fallen
into the dispenser unit/ice storage bin.
• Make sure all food zones in the appliance and dispenser unit/ice storage bin are
clean after service.
1. Diagnostic Procedure
The diagnostic procedure is a sequence check that allows you to diagnose the electrical
system and components. Before proceeding, check for correct installation, proper voltage
per nameplate, and adequate water supply.
Note: • When checking high voltage (115VAC), always choose a neutral (W) to establish
a good neutral connection.
• On 3-phase models, the neutral (W) is provided through MT. To confirm a good
neutral (W), check for 60VAC from neutral (W) to ground (GND). If 60VAC is
present, neutral (W) is good. If 60VAC is not present, check 208-230VAC main
power supply to MT. If 208-230VAC is present, check MT continuity.
• When checking voltage from the CB K1 connector (10 pin connector), pull CB
K1 connector out slightly to allow room for multimeter test leads contact.
1) Turn off the power supply, then access the control box. Clear any ice from BC.
2) Check that the 115VAC 10A fuses in the KMS and SRK are good.
Confirm that the location meets installation requirements:
KMS-2000MLJ
:
• The appliance is not intended for outdoor use. Normal operating ambient temperature
should be within 45°F to 100°F (7°C to 38°C).
• Allow 6" (15 cm) clearance at sides, rear, and top of the appliance for proper air
circulation and ease of maintenance and service.
• The appliance should not be located in a corrosive environment.
SRK-20J/3
:
• A dry and well ventilated area with 24" (61 cm) clearance in both front and rear for
proper air circulation and ease of maintenance and/or service should they be required.