Important Safety Information

Throughout this manual, notices appear to bring your attention to situations which could 
result in death, serious injury, damage to the appliance, or damage to property. 

 WARNING  

Indicates a hazardous situation which could result in death or 
serious injury. 

NOTICE 

Indicates a situation which could result in damage to the 
appliance or property.

IMPORTANT 

Indicates important information about the installation, use, and 
care of the appliance.

 WARNING

The appliance should be destined only to the use for which it has been expressly 
conceived. Any other use should be considered improper and therefore dangerous. 
The manufacturer cannot be held responsible for injury or damage resulting 
from improper, incorrect, and unreasonable use. Failure to install, operate, and 
maintain the appliance in accordance with this manual will adversely affect safety, 
performance, component life, and warranty coverage and may result in costly water 
damage.

To reduce the risk of death, electric shock, serious injury, or fire, follow basic 
precautions including the following:

• Only qualified service technicians should install and service the appliance.
• The appliance must be installed in accordance with applicable national, state, and 

local codes and regulations.

• Electrical connection must be hard-wired and must meet national, state, and local 

electrical code requirements. Failure to meet these code requirements could result 
in death, electric shock, serious injury, fire, or damage.

• The icemaker requires an independent power supply of proper capacity. See the 

nameplate for electrical specifications. Failure to use an independent power supply 
of proper capacity can result in a tripped breaker, blown fuse, damage to existing 
wiring, or component failure. This could lead to heat generation or fire.

• 

THE ICEMAKER MUST BE GROUNDED.

 Failure to properly ground the icemaker 

could result in death or serious injury.

• To reduce the risk of electric shock, do not touch the control switch or service switch 

with damp hands.

• Move the control switch to the "OFF" position and turn off the power supply before 

servicing. Lockout/Tagout to prevent the power supply from being turned back on 
inadvertently.

• Do not make any alterations to the appliance. Alterations could result in electric 

shock, serious injury, fire, or damage.

• The appliance is not intended for use by persons (including children) with reduced 

physical, sensory, or mental capabilities, or lack of experience and knowledge, 
unless they have been given supervision or instruction concerning use of the 
appliance by a person responsible for their safety.

Содержание KML-325MAJ

Страница 1: ...Instruction Manual Issued 9 23 2016 hoshizakiamerica com Low Profile Modular Crescent Cuber Models KML 325MAJ MWJ KML 500MAJ MWJ KML 700MAJ MWJ MRJ...

Страница 2: ...per installation is the responsibility of the installer Product failure or property damage due to improper installation is not covered under warranty Hoshizaki provides this manual primarily to assist...

Страница 3: ...stallation of Remote Condenser Unit 22 1 Location 22 2 Checks Before Installation 23 3 Setup 23 4 Line Set Size and Refrigerant Charge 23 5 Line Set Installation 24 6 Electrical Connection 27 7 Stacki...

Страница 4: ...nce with applicable national state and local codes and regulations Electrical connection must be hard wired and must meet national state and local electrical code requirements Failure to meet these co...

Страница 5: ...t and disconnect if required must meet national state and local electrical code requirements Failure to meet these code requirements could result in death electric shock serious injury fire or damage...

Страница 6: ...0 2A 120V 0 15A Maximum Fuse Size 20 AMPS 20 AMPS Max HACR Breaker USA Only 20 AMPS 20AMPS Max Circuit Breaker Canada Only 20 AMPS 20AMPS Minimum Circuit Ampacity 20 AMPS 20AMPS Design Pressure HI 467...

Страница 7: ...MAX Fan in URC Other 115V 0 15A 115V 0 15A 115V 0 15A Maximum Fuse Size 20 AMPS 20 AMPS 20 AMPS Max HACR Breaker USA Only 20 AMPS 20 AMPS 20 AMPS Max Circuit Breaker Canada Only 20 AMPS 20 AMPS 20 AM...

Страница 8: ...required The ice storage bin opening must match the bottom opening as in the illustration B Dimensions Connections 1 Air Cooled Models MAJ Units mm in Rear Side Bottom Model Shown KML 500MAJ KML 325M...

Страница 9: ...ey be required The ice storage bin opening must match the bottom opening as in the illustration KML 325MWJ KML 500MWJ KML 700MWJ A 559 22 659 26 B 515 20 1 4 615 24 1 4 C 505 19 7 8 605 23 7 8 D 403 1...

Страница 10: ...aintenance and or service should they be required The ice storage bin opening must match the bottom opening as in the illustration Rear Side Bottom Model Shown KML 700MRJ Model Shown KML 700MRJ Model...

Страница 11: ...h KML 700MRJ Rear Top Icemaker Model URC 9F Heat of Rejection AT 90 F 32 C WT 70 F 21 C KML 700MRJ 10 300 BTU hr NOTICE Allow 24 61 cm clearance at front and rear for proper air circulation and ease o...

Страница 12: ...the icemaker if the air temperature is going to go below 32 F 0 C See IV Preparing the Icemaker for Periods of Non Use The icemaker should not be located next to ovens grills or other high heat produc...

Страница 13: ...The remote condenser unit listed below is recommended Connection to a different remote condenser unit will void the warranty unless Hoshizaki approves a different remote condenser unit for your specif...

Страница 14: ...legs to level 5 Place the icemaker on top of the dispenser unit ice storage bin 6a Dispenser Unit Follow the dispenser unit adapter kit or top kit instructions for securing the icemaker If no instruct...

Страница 15: ...nit are supplied from the icemaker See II G 6 Electrical Connection Failure to properly ground the remote condenser unit could result in death or serious injury To reduce the risk of electric shock ma...

Страница 16: ...n the appliance until the proper water pressure is reached External filters strainers or softeners may be required depending on water quality Contact your local Hoshizaki Certified Service Representat...

Страница 17: ...pulled out for service Fig 4 Model Shown KML 700MRJ Air Cooled and Remote Models Remote Condenser Line Set Connections Remote Model Shut Off Valve Drain Valve Icemaker Icemaker Water Supply Inlet 1 2...

Страница 18: ...er a freeze cycle starts If the condenser drain outlet temperature is not in the proper range use a flat blade screwdriver to rotate the adjustment screw on the water regulating valve until the temper...

Страница 19: ...range Once the icemaker installation is complete confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts If the condenser return outlet temperature is not in the proper...

Страница 20: ...le starts If the condenser drain outlet temperature is not in the proper range use a flat blade screwdriver to rotate the adjustment screw on the water regulating valve until the temperature is in the...

Страница 21: ...range Once the icemaker installation is complete confirm the condenser return outlet temperature 5 minutes after a freeze cycle starts If the condenser return outlet temperature is not in the proper...

Страница 22: ...eriods outside of this normal temperature range may affect icemaker performance The maximum line length for the standard line sizes and refrigerant charge is 66 feet 20 m With larger line sizes and or...

Страница 23: ...t included Fig 11 Bolt with Split Lock Washer and Flat Washer Nut Plate Leg Bolt with Split Lock Washer and Flat Washer Nut 4 Line Set Size and Refrigerant Charge NOTICE The icemaker line set and remo...

Страница 24: ...d sealant on the fittings Use POE refrigerant oil or Parker Super O Lube only c Make sure the male fitting and female coupling are properly aligned then start the connection by hand to ensure that it...

Страница 25: ...s through the Schrader access ports on the Parker quick connect couplings if using an electronic leak detector and then raise the pressure using nitrogen gas 140 PSIG WARNING Do not use R 404A as a mi...

Страница 26: ...Insulated See II G 4 Line Set Size and Refrigerant Charge for details Icemaker Male Fitting Service Loop Apply POE Oil or Parker Super O Lube to Entire Male Fitting Threads Diaphragm O Ring Brush Mal...

Страница 27: ...box to the leads in the remote condenser unit s junction box Use wire of an appropriate gage and outdoor rating Do not connect the fan motor leads in the icemaker to incoming power source Do not conn...

Страница 28: ...door rating 5 Replace the junction box covers and the louver panel in their correct positions 7 Stacking Remote Condenser Unit 1 Install the lower remote condenser unit as described earlier in this se...

Страница 29: ...s sized as specified Are the water supply line shut off valve s and drain valve s installed Has the water supply pressure been checked to ensure a minimum of 10 PSIG and a maximum of 113 PSIG 8 Have t...

Страница 30: ...anel in its correct position 5 Turn on the power supply and allow the icemaker to operate for a total of 10 minutes 6 Remove the front panel then move the service switch to the DRAIN position Move the...

Страница 31: ...anitation regulations Maintenance Schedule Frequency Area Task Daily Scoop Clean the ice scoop using a neutral cleaner Rinse thoroughly after cleaning Bi Weekly Air Filters Inspect Wash with warm wate...

Страница 32: ...the evaporator turn off the power supply and turn it back on after 3 minutes The harvest cycle starts and the cubes will be removed from the evaporator 3 Turn off the power supply 4 Remove the front...

Страница 33: ...in its correct position 20 Turn on the power supply to fill the water tank with water 21 Turn off the power supply after 3 minutes 22 Remove the front panel 23 Move the service switch to the WASH posi...

Страница 34: ...r correct positions 6 Turn on the power supply to start the sanitizing process 7 Turn off the power supply after 15 minutes 8 Remove the front panel 9 Move the service switch to the DRAIN position 10...

Страница 35: ...r supply line drain valve 4 Allow the line to drain by gravity 5 Attach a compressed air or carbon dioxide supply to the icemaker water supply line drain valve 6 Move the control switch to the ICE pos...

Страница 36: ...ne drain valve If connected to a closed loop system also open the condenser return line drain valve 4 Attach a compressed air or carbon dioxide supply to the condenser water supply line drain valve 5...

Страница 37: ...sal The appliance contains refrigerant and must be disposed of in accordance with applicable national state and local codes and regulations Refrigerant must be recovered by properly certified service...

Страница 38: ...38 618 Hwy 74 South Peachtree City GA 30269 USA P 770 487 2331 F 770 487 3360 hoshizakiamerica com 1A3961 010...