30
I. Startup
1. Bin Control Setting
An ultrasonic sensor is used as the bin control to control the level of ice in the
dispenser unit/ice storage bin. The bin control setting must be set to match the
application to avoid possible icemaker movement, water leakage, or ice overflow.
WARNING
• Improper adjustment may adversely affect safety, performance, component life,
and warranty coverage.
• On dispenser unit applications, do not increase ice level above the recommended
setting listed below. Higher ice levels could result in icemaker movement, water
leakage, or ice overflow.
NOTICE
Do not allow top kits or top kit risers (if applicable) to interfere with the bin control
lens sensing area or the icemaker will not operate properly.
1) Make sure that the power supply is off. Remove the front, top, and right side panels to
allow access to the control board. Also remove the base cover. See Fig. 12. Note: If front
access to the control box is required, remove the control box mounting screws, then
slide the control box forward and rotate the control box for access. See Fig. 13.
2) Confirm the correct control board bin control setting required for your application and
adjust as detailed below.
Application
Bin Control Setting
Reference
Standard Ice Storage Bins (Factory Default)
1
See Fig. 14
Hoshizaki DB and DM Dispensers
2
Coca-Cola Freestyle
®
Dispensers
3
Non-Hoshizaki Dispensers
Measurement Required
See Fig. 15
Fig. 13
Control Box
Control Box
Mounting Screws
Control Box
Control Board
Icemaker
Base Cover
Fig. 12