ENGLISH
3
I. INSTALLATION INSTRUCTIONS
1. UNPACKING
WARNING
Children should not be allowed in reach of the packaging elements
(plastic bags and expanded polystyrene) as they are potential
sources of danger.
CAUTION
Remove shipping carton, tape(s) and packing. If packing material
is left in the icemaker, it will not work properly.
6. Do not place anything on top of the icemaker or in front of the
louver.
7. This icemaker will not work at subfreezing temperatures. To
prevent damage to the water supply line, drain the icemaker
when air temperature is below zero (see “II. 2. PREPARING
THE ICEMAKER FOR LONG STORAGE”).
3. INSTALLATION
* Incorrect installation can cause harm to people, animals or things, for
which the manufacturer cannot be held responsible.
* Place the icemaker in the selected permanent site.
* The appliance must be positioned so that the plug is accessible.
4. ELECTRICAL CONNECTIONS
WARNING
THIS APPLIANCE MUST BE EARTHED
This icemaker requires an earth that meets the national and local
electrical code requirements. To prevent possible severe electrical
shock to individuals or extensive damage to equipment, install a
proper earth wire to the icemaker. Remove the plug from the mains
socket before any maintenance, repairs or cleaning is undertaken.
* This appliance requires a separate 220 - 240VAC, 10A supply. The
electrical supply must be protected by a suitable circuit breaker.
* The main control box fuse is rated at 5A and should only be replaced
by a quali
fi
ed service engineer.
* Usually an electrical permit and services of a licensed electrician are
required.
5. WATER SUPPLY AND DRAIN CONNECTIONS
WARNING
Connect to potable water supply only.
* The connections to the mains water supply must be made in
accordance with the countries’ current requirements of the Water
Supply or Water Fittings Regulations.
* Icemaking water must be potable water. Where scaling can be
caused by water quality, installation of an external
fi
lter or softener
is recommended. Contact your local water treatment professional or
Hoshizaki service agent.
* Water supply pressure should be minimum 0.07 MPa (0.7 bar) and
maximum 0.8 MPa (8 bar). If the pressure exceeds 0.8 MPa (8 bar),
use a pressure reducing valve. Do NOT throttle back the supply tap.
* Be sure to use the new hose-sets supplied with the appliance. Do not
reuse any old hose-sets.
* A plumbing permit and services of a licensed plumber may be required
in some areas.
* Water should drain into an open trap.
* The icemaker drain is gravity
fl
ow, so ensure drain pipe has an
adequate pitch or fall.
* To prevent a back
fl
ow into the storage bin, the outlet hose must be
laid as shown in Fig. 2.
1) After removing the packaging, make sure that the icemaker is in good
condition. If in doubt, please do not use the equipment but apply to
professionally quali
fi
ed personnel.
2) Remove shipping tape holding the door and separator.
3) Remove the protective plastic
fi
lm from the exterior. If the icemaker
is exposed to the sun or to heat, remove the
fi
lm after the icemaker
cools.
4) Remove the package of accessories, and check the contents:
a) Outlet Hose
1
b) Scoop
1
c) Adjust Bolt
4
2. LOCATION
IMPORTANT
1. This icemaker is not intended for outdoor use. Normal operating
ambient temperature should be within 7°C to 40°C. Normal
operating water temperature should be within 7°C to 35°C.
Operation of the icemaker, for extended periods, outside
of these normal temperature ranges may affect production
capacity.
2. The icemaker should not be located next to ovens, grills or
other high heat producing equipment.
3. The location should provide a
fi
rm and level foundation for the
equipment.
4. Allow 15 cm clearance at rear and sides for proper air circulation
and ease of maintenance and/or service should they be
required.
5. This appliance is not suitable for installation in an area where
a water jet could be used and where dripping is not allowed.
Fig. 1
Top Panel
Separator
Control Switch
Icemaking
Mechanism
Door
Accessories
(inside bin)
Louver
Control Box
Air Filter
Refrigeration
Circuit