B. Cleaning and Sanitizing Instructions
The icemaker must be cleaned and sanitized at least once a year. More frequent
cleaning and sanitizing may be required in some water conditions.
WARNING
• To prevent injury to individuals and damage to the icemaker, do not use ammonia
type cleaners.
• Carefully follow any instructions provided with the bottles of cleaning and
sanitizing solution.
• Always wear liquid-proof gloves and goggles to prevent the cleaning and sanitizing
solutions from coming into contact with skin or eyes.
NOTICE
To prevent damage to the water pump seal, do not leave the control switch in the
"WASH" position for extended periods when the water tank is empty.
IMPORTANT
• The cleaning valve is opened during cleaning and sanitizing to allow solution flow
to the inside of the evaporator. It should be closed for all icemaking operation. The
compressor will not operate unless this valve is completely closed.
• To close the cleaning valve, the valve handle should be at a right angle to the
valve body. To open the cleaning valve, the valve handle should be parallel to the
valve body.
1. Cleaning Procedure
1) Dilute Hoshizaki "Scale Away" with warm water. Refer to the table.
Model
Scale Away
Warm Water
KM-1601 and Smaller
27 fl. oz. (800 ml)
5 gal. (19 l)
KM-1900 and Larger
38 fl. oz. (1,124 ml)
7 gal. (26 l)
2) Remove all ice from the evaporator and the dispenser unit/ice storage bin.
Note: To remove cubes on the evaporator, turn off the power supply and turn it back on
after 3 minutes. The harvest cycle starts and the cubes will be removed from the
evaporator.
3) Turn off the power supply.
4) Remove the front panel, then remove the insulation panel by removing the thumbscrew,
lifting up the panel slightly, and pulling it towards you.
5) Remove the drain plug located on the lower front part of the ice chute. See Fig. 24.
Allow the water tank to drain.