57
VIII. Technical Information
We reserve the right to make changes in specifications and design without prior notice.
A. Specification and Performance Data
Pressure data is recorded at 5 min. into freezing cycle. The data not in bold
should be used for reference only.
1. KM-1301SAJ
Specification Sheet
AC SUPPLY VOLTAGE
208-230/60/1
AMPERAGE
12.4 A
MINIMUM CIRCUIT AMPACITY
20 A
MAXIMUM FUSE SIZE
20 A
ELECTRIC & WATER CONSUMPTION 90/70°F
70/50°F
ELECTRIC W (kWH/100 lbs.)
2310(4.27)
2180(3.83)
WATER gal./24HR (gal./100 lbs.)
273(21.0)
665(48.8)
ICE PRODUCTION PER CYCLE
28.6 lbs. (13 kg) 1440pcs.
BIN CONTROL SYSTEM
Mechanical
REFRIGERANT CHARGE
R404A, 3 lb. 15.5 oz. (1800g)
Performance Data Sheet
70/21
1365
619
1346
611
1315
597
80/27
1351
613
1322
599
1288
584
90/32
1346
611
1301
590
1268
575
lbs./day kg./day
100/38
1338
607
1293
587
1237
561
70/21
80/27
90/32
watts
100/38
70/21
665
2.52
551
2.08
484
1.83
80/27
578
2.19
399
1.51
383
1.45
90/32
551
2.08
273
1.03
234
0.89
gal./day m3/day
100/38
416
1.57
264
1.00
198
0.75
70/21
80/27
90/32
min.
100/38
70/21
80/27
90/32
min.
100/38
70/21
253
17.8
271
19.1
297
20.8
80/27
267
18.8
295
20.7
321
22.5
90/32
271
19.1
315
22.1
341
24.0
PSIG kg/cm2G
100/38
276
19.4
321
22.6
365
25.7
70/21
55
3.9
56
3.9
58
4.1
80/27
56
3.9
57
4.0
59
4.2
90/32
56
3.9
58
4.1
60
4.2
PSIG kg/cm2G
100/38
56
4.0
58
4.1
62
4.4
19,400 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
TOTAL HEAT OF REJECTION FROM COMPRESSOR
3,200 BTU/h [AT 90ºF (32ºC) / WT 70ºF (21ºC)]
2.1
HEAD PRESSURE
SUCTION PRESSURE
32
30
35
TOTAL HEAT OF REJECTION FROM CONDENSER
HARVEST CYCLE TIME
4.9
4.3
3.8
4.4
3.4
3.2
4.3
2.7
2.3
3.5
2.6
2232
2325
2430
APPROXIMATE WATER
CONSUMPTION PER 24 HR.
FREEZING CYCLE TIME
31
30
32
30
30
33
30
29
32
APPROXIMATE ELECTRIC
CONSUMPTION
2180
2218
2277
2209
2268
2331
2218
2310
2373
APPROXIMATE ICE PRODUCTION
PER 24 HR.
AMBIENT TEMP.
(ºF/ºC)
WATER TEMP. (ºF/ºC)
50/10
70/21
90/32
ENG.F-011.1.0205