![Hoshizaki F-1001MAJ Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/hoshizaki/f-1001maj/f-1001maj_instruction-manual_2165084006.webp)
6
I. Specifications
A. Electrical and Refrigerant Data
The rating label and nameplate provide electrical and refrigerant data. The rating label
can be seen by removing the front panel. The nameplate is located on the rear panel. For
certification marks, see the nameplate.
We reserve the right to make changes in specifications and design without prior notice.
1. F-450MAH(-C)
Single Phase
Model Number
F-450MAH(-C)
AC Supply Voltage
115-120/60/1
Compressor
120V 7.5RLA 54.5LRA
Gear Motor
115V 2.4FLA 1/4HP
Fan Motor
115V 0.85FLA 1/15HP
Other
115V 0.03A
Maximum Fuse Size 20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
Design Pressure
HI-427PSI LO-230PSI
Refrigerant
404A 1 LB.
2. F-801M_H(-C)
Single Phase
Model Number
F-801MAH(-C)
F-801MWH(-C)
AC Supply Voltage
115-120/60/1
115-120/60/1
Compressor
120V 7.5RLA 54.5LRA
120V 7.5RLA 54.5LRA
Gear Motor
120V 3.0FLA 1/4HP
120V 3.0FLA 1/4HP
Fan Motor
120V 0.85FLA 1/15HP
--- --- ---
Other
120V 0.03A
120V 0.03A
Maximum Fuse Size 20 AMPS
20 AMPS
Max. HACR Breaker
(USA Only)
20 AMPS
20 AMPS
Max. Circuit Breaker
(Canada Only)
20 AMPS
20 AMPS
Minimum Circuit
Ampacity
20 AMPS
20 AMPS
Design Pressure
HI - 427PSI LO - 230PSI
HI - 427PSI LO - 230PSI
Refrigerant
404A 1 LB. 12 OZ.
404A 10.7 OZ.