Shut-Off Valve
Drain Valve
Icemaker
Water Supply
Inlet
1/2" FPT
Storage Bin
Drain Outlet
3/4" FPT
Icemaker
Drain Outlet
3/4" FPT
1. Icemaker
Icemaker Water
Supply Inlet
Minimum Icemaker
Water Supply Line Size
Icemaker Drain
Outlet
Minimum Icemaker
Drain Line Size
1/2" Female Pipe
Thread (FPT)
1/4" Nominal ID
Copper Water Tubing or
Equivalent
3/4" Female Pipe
Thread (FPT)
3/4" Nominal
ID Hard Pipe or
Equivalent
• An icemaker water supply line shut-off valve and drain valve must be installed.
• Be sure there is sufficient extra water supply line and drain line for the appliance to be
pulled out for service.
Icemaker
Minimum 1/4" Nominal ID Copper Water
Tubing or Equivalent
Minimum 3/4" Nominal ID Hard Pipe or Equivalent
Vent Tube
Minimum 3/4" Nominal ID Hard Pipe or Equivalent
Vent Tube
2-inch (5-cm) air gap
Floor Drain
Separate piping to
approved drain. Leave a
two-inch (5 cm) vertical air
gap between the end of
each pipe and the drain.
Be sure there is sufficient
extra water supply line and
drain line for the appliance
to be pulled out for service.
Fig. 3
Model Shown:
DKM-500BAH
Air-Cooled Model