36
D. Condenser
Check the condenser once a year, and clean if required by following the steps below.
More frequent cleaning may be required depending on location.
WARNING
Condenser fins are sharp. Use care when cleaning.
1) Move the control switch to the "OFF" position, then unplug the appliance from the
electrical outlet.
WARNING! To reduce the risk of electric shock, do not touch the
control switch or plug with damp hands.
2) Remove the screws securing the front panel, then remove it. See Fig. 33.
3) Remove the screws securing the louver, then remove it.
4) Use a brush attachment on a vacuum cleaner to gently clean the condenser fins. Do not
use too much force, otherwise the fins could be damaged.
5) Replace the louver and front panel in their correct positions. Ensure that the screws are
securely in place.
6) Plug the appliance back in. Move the control switch to the "ICE" position to start the
automatic icemaking process.
Front Panel
Louver
Fig. 33
Screws
Screws
Condenser