![Hoshizaki AM-50BAJ Скачать руководство пользователя страница 31](http://html1.mh-extra.com/html/hoshizaki/am-50baj/am-50baj_instruction-manual_2164898031.webp)
31
IV. Maintenance
This icemaker must be maintained in accordance with the instruction manual and
labels provided with the icemaker. Consult with your local Hoshizaki Certified Service
Representative about maintenance service.
WARNING
• Only qualified service technicians should service this icemaker.
• Failure to install, operate, and maintain the icemaker in accordance with this
manual will adversely affect safety, performance, component life, and warranty
coverage.
• Move the control switch to the "OFF" position and unplug the icemaker from the
electrical outlet before servicing.
• To reduce the risk of electric shock, do not touch the control switch or plug with
damp hands.
•
CHOKING HAZARD: Ensure all components, fasteners, and thumbscrews are
securely in place after any maintenance is performed. Make sure that none have
fallen into the ice storage bin.
• After service, make sure that there are no wires pinched between the panels and
icemaker. Make sure you do not damage or pinch the water supply line, drain line,
or power cord.
A. Maintenance Schedule
The maintenance schedule below is a guideline. More frequent maintenance may be
required depending on water quality, the icemaker's environment, and local sanitation
regulations.
Maintenance Schedule
Frequency Area
Task
Weekly
Scoop
Clean the scoop using a neutral cleaner. Rinse thoroughly after cleaning.
Monthly
External Water
Filters
Check for proper pressure and change if necessary.
Icemaker Exterior
Wipe down with clean, soft cloth. Use a damp cloth containing a neutral
cleaner to wipe off oil or dirt build up. Clean any chlorine staining (rust
colored spots) using a non-abrasive cleaner like Zud or Bon Ami.
Every 3
Months
Ice Storage Bin
Drain
Maintain as outlined in "IV.C. Ice Storage Bin Drain."
Yearly
Icemaker and Ice
Storage Bin
Clean and sanitize per the cleaning and sanitizing instructions provided in
this manual. See "IV.B. Cleaning and Sanitizing Instructions."
Optional Drain
Pump (HS-5061)
Test as outlined in "IV.E. Optional Drain Pump HS-5061."
Water Supply Inlet Close the icemaker water supply line shut-off valve and drain the water
system. Clean the water supply inlet screen.
Condenser
Inspect. Clean if necessary. See "IV.D. Condenser."
Water Hoses
Inspect the water hoses and clean/replace if necessary.