LEAFLET No P82419

ISSUE 1

P

Pa

ag

ge

e  4

4

Email: [email protected]

Website: www.horstmann.co.uk

The F328m / F322e valve with auxiliary switch has been designed

to control the water circulation in fully pumped systems, which

employs a single pump for both Hot water  and  Central  heating

circuits, by  allowing  the  flow  to  either  or  both  circuits.

Horstmann Controls Limited

Bristol 

BS4 1UP

t:0117 9788 773 - f:0117 9788 701

M

Mo

ot

to

or

r  s

su

up

pp

plly

y  v

vo

ollt

ta

ag

ge

e::  230V AC, 50Hz

P

Po

ow

we

er

r  c

co

on

ns

su

um

mp

pt

tiio

on

n:: <6.5W

L

Le

ea

ad

d  s

su

up

pp

plliie

ed

d:: 1 metre 5 core cable. Industry standard colours used

E

Ea

ar

rt

th

h  c

co

on

nn

ne

ec

ct

tiio

on

n  r

re

eq

qu

uiir

re

ed

d..

O

Olliiv

ve

e  S

Siiz

ze

e::    F228m - 28

mm 

(Metric)

F228e - 1 

1/4

inch (Imperial)  

O

Op

pe

er

ra

at

tiin

ng

g  f

fllo

ow

w  t

te

em

mp

pe

er

ra

at

tu

ur

re

e:: Up to 80

o

C

S

Sw

wiit

tc

ch

h  r

ra

at

tiin

ng

g:: 5 Amps

M

Ma

ax

xiim

mu

um

m  a

am

mb

biie

en

nt

t  t

te

em

mp

pe

er

ra

at

tu

ur

re

e:: 50

o

C

M

Ma

ax

xiim

mu

um

m  s

st

ta

at

tiic

c  p

pr

re

es

ss

su

ur

re

e:: 21 Bar

M

Ma

ax

xiim

mu

um

m  d

diif

ff

fe

er

re

en

nt

tiia

all  p

pr

re

es

ss

su

ur

re

e::  2 Bar

P

Piip

pe

e  f

fiit

tt

tiin

ng

g  s

siiz

ze

e:: 28

mm

compression

A

Ac

ct

tu

ua

at

to

or

r:: Maximum time to power open - 20 seconds

Maximum time to spring close - 10 seconds

O

Ov

ve

er

rr

riid

de

e  lle

ev

ve

er

r::

For manual operating to open valve for system draining or filling. 

During normal operation, the lever must be in the auto position.

SPECIFICATION

P

Pa

ag

ge

e  1

1

INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED

PERSON  AND  IN  ACCORDANCE   WITH  THE  CURRENT EDITION  OF  THE I.E.E.  WIRING

REGULATIONS. A CLASS ‘A’ SWITCH (HAVING  CONTACT  SEPARATION OF AT LEAST 3MM IN

ALL POLES) MUST BE INCORPORATED IN THE FIXED WIRING AS A MEANS OF DISCONNECTING

THE SUPPLY, NORMALLY AT THE CONSUMER UNIT. THE SYSTEM MUST BE APPROPRIATELY

FUSED.

W

WA

AR

RN

NIIN

NG

G :: IIS

SO

OL

LA

AT

TE

E  M

MA

AIIN

NS

S  S

SU

UP

PP

PL

LY

Y  B

BE

EF

FO

OR

RE

E  C

CO

OM

MM

ME

EN

NC

CIIN

NG

G  IIN

NS

ST

TA

AL

LL

LA

AT

TIIO

ON

N

COMMISSIONING

C

CE

EN

NT

TR

RA

AL

L H

HE

EA

AT

TIIN

NG

G O

ON

NL

LY

Y..

Set the cylinder thermostat to minimum or turn the HW off at the programmer.

Set the room thermostat to maximum and turn the CH on at the programmer.

The valve should close Port B. The boiler should fire, pump run and the pipe on the Port A side

should get hot.

H

HO

OT

T W

WA

AT

TE

ER

R A

AN

ND

D C

CE

EN

NT

TR

RA

AL

L H

HE

EA

AT

TIIN

NG

G..

Set  the  room  and  cylinder  thermostat  to  maximum  and  turn  the  HW  and  CH  on  at

the  programmer.

The valve should be in the mid-position. The boiler should fire, pump run and the pipes on

both Port A side and Port B should get hot.

Reset both thermostats and the programmer to their normal settings.

P

Plle

ea

as

se

e  n

no

ot

te

e the above assumes that both programmer and thermostats are being used. If this

is not the case, ignore the action described for the item not fitted.