Horstmann ChannelPlus H37XL Series 2 Скачать руководство пользователя страница 1

C

C

H

H

A

A

N

N

N

N

E

E

L

L

P

P

L

L

U

U

S

S

  H

H

3

3

7

7

X

X

L

L

  S

S

E

E

R

R

IIE

E

S

S

  2

2

IIN

N

S

S

T

T

A

A

L

L

L

L

A

A

T

T

IIO

O

N

N

  II

N

N

S

S

T

T

R

R

U

U

C

C

T

T

IIO

O

N

N

S

S

  

INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON

AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.

W

WA

AR

RN

NIIN

NG

G :: IIS

SO

OL

LA

AT

TE

E  M

MA

AIIN

NS

S  S

SU

UP

PP

PL

LY

Y  B

BE

EF

FO

OR

RE

E  C

CO

OM

MM

ME

EN

NC

CIIN

NG

G  IIN

NS

ST

TA

AL

LL

LA

AT

TIIO

ON

N

F

FIIT

TT

TIIN

NG

G  T

TH

HE

E  B

BA

AC

CK

KP

PL

LA

AT

TE

E

Once the Backplate has been removed from the

packaging  please  ensure  the  programmer  is

re-sealed to prevent damage from dust, debris

etc.

The Backplate should be fitted with the wiring

terminals located at the top and in a position

which allows the relevant clearances around

the programmer. (See diagram)  

D

DIIR

RE

EC

CT

T  W

WA

AL

LL

L  M

MO

OU

UN

NT

TIIN

NG

G

Offer the plate to the wall in the position where the programmer is to be mounted, remembering that

the Backplate fits to the right hand end of the programmer.

Mark the fixing positions through the slots in the Backplate (Fixing centres 60.3mm), drill and plug the

wall, then secure the plate in position. The slots in the Backplate will compensate for any 

misalignment of the fixings.

W

WIIR

RIIN

NG

G  B

BO

OX

X  M

MO

OU

UN

NT

TIIN

NG

G

The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662,

using two M3.5 screws.

ChannelPlus series 2 programmers are suitable for mounting on a flat surface only, they must not be

positioned on a surface mounted wall box or on unearthed metal surfaces.  

E

EL

LE

EC

CT

TR

RIIC

CA

AL

L  C

CO

ON

NN

NE

EC

CT

TIIO

ON

NS

S

All necessary electrical connections should now be made. Flush wiring can enter from the rear through

the aperture in the Backplate. Surface wiring can only enter from beneath the programmer and must be

securely clamped.

The mains supply terminals are intended to be connected to the supply by means of fixed wiring.

The recommended cable sizes are 1.0mm

2

or 1.5mm

2

.

Page 1

Page 4

LEAFLET No P82731

ISSUE 1

S

SP

PE

EC

CIIF

FIIC

CA

AT

TIIO

ON

N  H

H3

37

7X

XL

L  S

SE

ER

RIIE

ES

S  2

2

C

Co

on

nt

ta

ac

ct

t  t

ty

yp

pe

e::  Micro dis-connection

C

Co

on

nt

ta

ac

ct

t  r

ra

at

tiin

ng

g:: 3(1)Amps 230-240V AC

P

Po

ow

we

er

r  s

su

up

pp

plly

y::  230V AC 50Hz

O

Op

pe

er

ra

at

tiin

ng

g  T

Te

em

mp

pe

er

ra

at

tu

ur

re

e  r

ra

an

ng

ge

e:: 0

o

C to 40

o

C

D

Do

ou

ub

blle

e  iin

ns

su

ulla

at

te

ed

d..

D

Diir

rt

t  p

pr

ro

ot

te

ec

ct

tiio

on

n::  Normal situations.

E

En

nc

cllo

os

su

ur

re

e  p

pr

ro

ot

te

ec

ct

tiio

on

n:: IP30

P

Pu

ur

rp

po

os

se

e  o

of

f  c

co

on

nt

tr

ro

oll:: Electronic time switch

IIn

nd

de

ep

pe

en

nd

de

en

nt

tlly

y  m

mo

ou

un

nt

te

ed

d  c

co

on

nt

tr

ro

oll  f

fo

or

r  s

su

ur

rf

fa

ac

ce

e  m

mo

ou

un

nt

tiin

ng

g..

O

Op

pe

er

ra

at

tiin

ng

g  t

tiim

me

e  lliim

miit

ta

at

tiio

on

n::  Continuous

B

Ba

at

tt

te

er

ry

y  T

Ty

yp

pe

e:: Lythium

C

Ca

as

se

e  m

ma

at

te

er

riia

all:: Thermoplastic, flame retardant

D

Diim

me

en

ns

siio

on

ns

s:: 163mm x 101mm x 37mm

D

Diis

sp

plla

ay

y::  Fully graphical LCD, back-lit 

C

Cllo

oc

ck

k:: 24hour /12 hour AM/PM

D

Diis

sp

plla

ay

y  t

tiim

me

e  a

ad

djju

us

st

tm

me

en

nt

t:: 1 Minute steps

S

Sw

wiit

tc

ch

he

ed

d  t

tiim

me

e  a

ad

djju

us

st

tm

me

en

nt

t::  10 Minute steps

P

Pr

ro

og

gr

ra

am

mm

me

e  s

se

elle

ec

ct

tiio

on

n:: Auto, On all day, On constant, Off, Holiday

O

Op

pe

er

ra

at

tiin

ng

g  p

pe

er

riio

od

ds

s  p

pe

er

r  d

da

ay

y::  Three for Heating 1, Heating 2 and

Water (separate daily programme for each Channel)

O

Ov

ve

er

rr

riid

de

e::

Boost, 1 or 2 Hours

Extension to ON period, 1Hr or 2Hr

Instant Advance

B

Ba

ac

ck

kp

plla

at

te

e::  9 Pin terminal connection

Horstmann Controls Limited

Bristol 

BS4 1UP

t:0117 9788 773 - f:0117 9788 701

Email: [email protected]

Website: www.horstmann.co.uk

Lower the front flap of the unit. On third Channel press

the ADVANCE(Enter) and SELECT(Blue) buttons together

then release the buttons and the programmer will

return to the preset factory settings. 

R

RE

ES

SE

ET

T  P

PR

RO

OC

CE

ED

DU

UR

RE

E

P

PL

LE

EA

AS

SE

E  N

NO

OT

TE

E;; Using this procedure will restore the ChannelPlus to the original factory 

programme settings, the time setting will also default to 1

1s

st

t  JJa

an

nu

ua

ar

ry

y  2

20

00

05

5.

Electronic equipment can in some circumstances be affected by electrical interference. If the display

becomes frozen or scrambled; or if you wish to revert back  to the  default  settings  please  use  the

following procedure.

R

RE

ES

SE

ET

TT

TIIN

NG

G  T

TH

HE

E  C

CH

HA

AN

NN

NE

EL

LP

PL

LU

US

S  H

H3

37

7X

XL

L  S

SE

ER

RIIE

ES

S  2

2

G

GE

EN

NE

ER

RA

AL

L  IIN

NF

FO

OR

RM

MA

AT

TIIO

ON

N

B

BA

AT

TT

TE

ER

RY

Y

The  programmer  is  fitted  with  a  non-rechargeable,  non-serviceable  long  life  battery,  which  will

maintain the programmed time settings with the mains supply disconnected. 

THIS RESERVE SHOULD BE SUFFICIENT TO COVER POWER INTERRUPTIONS DURING THE LIFE OF THE UNIT.

During power interruptions the display will be blank.

S

SE

ER

RV

VIIC

CE

E  A

AN

ND

D  R

RE

EP

PA

AIIR

R

This programmer is NOT user serviceable. Please do not dismantle the unit. In the unlikely event of a

fault developing please refer to the RESETTING THE PROGRAMMER section of this user guide located on

page 2. If this fails to resolve the  problem  please  contact  a  local  heating engineer or a qualified

electrician.

ADVANCE

SELECT

BOOST

RESE

T

H

Ho

or

rs

st

tm

ma

an

nn

n   C

Ch

ha

an

nn

ne

ellP

Pllu

us

s   H

H3

37

7X

XL

L   S

Se

er

riie

es

s   2

2   -

-   T

Th

hr

re

ee

e   C

Ch

ha

an

nn

ne

ell   P

Pr

ro

og

gr

ra

am

mm

me

er

r..   Each

channel offers up to three programmed operating periods per day, seven days

a week, with  three independent Boost and Advance control on Fully Pumped

Systems.  This model offers a fully  graphical, back-lit display combined with

simple menu driven programming.

It  is  also a  suitable  direct  replacement  for  existing  Horstmann  ChannelPlus

H37XL  programmers, utilising existing wiring and backplate connections.

Отзывы: