INSTALLATION AND CONNECTION SHOULD ONLY BE CARRIED OUT BY A SUITABLY QUALIFIED PERSON
AND IN ACCORDANCE WITH THE CURRENT EDITION OF THE IEE WIRING REGULATIONS.
WARNING : ISOLATE MAINS SUPPLY BEFORE COMMENCING INSTALLATION
FITTING THE BACKPLATE
Once the Backplate has been removed from
the packaging please ensure the programmer
is re-sealed to prevent damage from dust,
debris etc.
The Backplate should be fitted with the wiring
terminals located at the top and in a position
which allows the relevant clearances around
the programmer. (See diagram)
DIRECT WALL MOUNTING
Offer the plate to the wall in the position where the programmer is to be mounted, remembering that
the Backplate fits to the right hand end of the programmer.
Mark the fixing positions through the slots in the Backplate (Fixing centres 60.3mm), drill and plug the
wall, then secure the plate in position. The slots in the Backplate will compensate for any
misalignment of the fixings.
WIRING BOX MOUNTING
The Backplate may be fitted directly on to a single gang steel flush wiring box complying with BS4662,
using two M3.5 screws.
ChannelPlus programmers are suitable for mounting on a flat surface only, they must not be
positioned on a surface mounted wall box or on unearthed metal surfaces.
ELECTRICAL CONNECTIONS
All necessary electrical connections should now be made. Flush wiring can enter from the
rear through the aperture in the Backplate. Surface wiring can only enter from beneath the
programmer and must be securely clamped.
The mains supply terminals are intended to be connected to the supply by means of fixed wiring.
The recommended cable sizes are 1.0mm
2
or 1.5mm
2
.
PAGE 1
PAGE 4
LEAFLET No P32646
ISSUE 6
SPECIFICATION H37XL
GENERAL INFORMATION
Before handing over the installation to the user, always ensure that the system responds
correctly on all control programmes and that other electrically operated equipment and controls are
correctly adjusted.
EXPLAIN HOW TO OPERATE THE CONTROLS AND HAND OVER THE USERS OPERATING INSTRUCTIONS TO THE USER.
ADVANCE
BOOST
SELECT
UPON COMPLETION OF INSTALLATION PLEASE RESET THE PROGRAMMER BEFORE SETTING THE HEATING AND
HOT WATER OPERATIONS.
Contact type: Micro dis-connection
Contact rating: 3(1)Amps 230-240V AC
Power supply: 230-240V AC 50Hz
Operating Temperature range:
0oC to 55oC
Double insulated.
Dirt protection: Normal situations.
Enclosure protection: IP30
Purpose of control: Electronic time switch
Independently mounted control for surface mounting.
Operating time limitation: Continuous
Type 1 Action
Battery Reserve: 10 months continuous operation(minimum)
Case material: Thermoplastic, flame retardant
Dimensions: 163mm x 101mm x 33mm
Display:
Liquid crystal
Clock: 12 hour AM/PM
Display time adjustment: 1 Minute steps
Switched time adjustment: 10 Minute steps
Programme selection: Auto, On all day, On constant, Off, Holiday
Operating periods per day: Three for Heating 1, Heating 2 and
Water (separate daily programme for each Channel)
Override:
Boost, 1 or 2 Hours
Extension to ON period, 1or 2 Hour
Instant Advance
Backplate:
9 Pin terminal connection
FITTING THE PROGRAMMER (Cont.)
The unit can now be programmed to suit the User’s requirements.
Please refer to the User’s Guide provided.
Horstmann’s ChannelPlus H37XL
is the unique Three Channel programmer
which allows up to three operating periods per day, seven days a week,
on two independent Heating and one Hot water zone.
If the unit is installed with the commissioning switch in the OFF
position, the word ‘SWITCH BATTERY ON’ will flash on the
display when the mains power is supplied.
The switch will need to be moved into the correct position
before proceeding further.
SWITCH
BATTERY
ON
Lower the front flap of the unit. On the Hot water channel press the
ADVANCE and SELECT buttons together, release the buttons and the
programmer will return to the preset factory settings.
The Preset factory settings are illustrated on page 2 of the USER GUIDE.
RESETTING THE PROGRAMMER
Horstmann Controls Limited
Bristol
BS4 1UP
t:0117 9788 773 - f:0117 9788 701
Email: [email protected]
Website: www.horstmann.co.uk