CentaurPlus ZW and HRT4-ZW  

Installation Instructions

The Horstmann CentaurPlus ZW combined wireless room stat and timeswitch 
allows a combi boiler system to have a room thermostat added without the 
need for any additional wiring.

Replacing the existing timeswitch with the CentaurPlus ZW will allow the room 
thermostat to be connected wirelessly producing immediate energy savings in 
houses where no previous room thermostat has been fitted.

The device is intended to upgrade existing combi boiler systems that do not 
have an existing room thermostat. It is not intended for new installations where 
it will be necessary to install two heating zones in order to comply with current 
Building Regulations.

1

Содержание CentaurPlus ZW

Страница 1: ...g timeswitch with the CentaurPlus ZW will allow the room thermostat to be connected wirelessly producing immediate energy savings in houses where no previous room thermostat has been fitted The device...

Страница 2: ...le circuit diagram for a typical combi boiler installation is shown below This diagram is schematic and should be used for guidance only N N E L L 1 2 3 4 For precise terminal connection information p...

Страница 3: ...mounted remembering that the backplate fits to the left hand end of the control Mark the fixing positions through the slots on the backplate fixing centres of 60 3mm drill and plug the wall then secu...

Страница 4: ...ty must be maintained and all bare earth connectors must be sleeved Ensure no earth conductors are left protruding outside the central space enclosed by the backplate Internal diagram C17 ZW The Centa...

Страница 5: ...of the unit locate into the terminal slots in the backplate Tighten the two captive retaining screws to fix the unit securely Then switch on the mains supply On completion of the installation please r...

Страница 6: ...IT During power interruptions the display will be blank after 3 days the current time of day will be lost These measures are to prolong the battery life SERVICEAND REPAIR This timeswitch is NOTuser se...

Страница 7: ...ide optimum comfort with close control of the energy used to heat the home without the need for additional wiring or unsightly cable runs The HRT4 ZW will only operate when 2 x AAA batteries have been...

Страница 8: ...o make the boiler switch on and off N B There is a half second delay in switching On and Off on receipt of the commands There is no click from the thermostat which is silent in operation but there wil...

Страница 9: ...ollowing the procedure shown under Stage 1 of the pairing instructions Only use Stage 2 if a radio link cannot be successfully established between the two devices Stage 2 only used if above procedure...

Страница 10: ...l far more efficiently than any traditional thermostat When used with a condensing boiler the TPI thermostat will help to save energy as the control algorithm allows the boiler to operate in condensin...

Страница 11: ...Ensure that there will be enough space to allow easy access to the two retaining screws located at the base of the wall plate Before fixing the wall plate in position check to see that the thermostat...

Страница 12: ...xtension to On period instant advance Mounting Industry standard 6 terminal plug in wall plate Transmitter Frequency 868MHz Design Standard EN60730 2 7 IP30 EN300 220 R TTE Directive EN301 489 Thermos...

Отзывы: