Troubleshooting
Malfunction
Possible cause
Remedy
The placing quantity is too low. The sealing lip in the metering unit is worn. Replace the sealing lip.
The placing quantity is set too low.
Check the adjustment on the
terminal and correct as required.
The pressure hopper is leaking.
Check the hopper for leak tightness
and replace the seals if necessary.
The pneumatic system is leaking.
Check the distributor and all
pneumatic hoses for leak tightness.
Replace the respective components
if necessary.
No draught on coulters
The air intake grid is soiled.
Clean the air intake grid.
The drilling lines are blocked.
Clean the drilling lines.
Bearing damage on fan
• Normal wear
• Fan did run with excessive power
• Unbalance in impeller wheel
• Replace bearings.
• Replace the impeller wheel or clean
from dirt.
• Never run the fan without connect-
ed pneumatic hoses.
46
MF