![horsch LEEB PT 330 Скачать руководство пользователя страница 160](http://html1.mh-extra.com/html/horsch/leeb-pt-330/leeb-pt-330_operating-instructions-manual_2164094160.webp)
Piston diaphragm pump suction filter
1.
Unscrew the filter. It is located on the un
-
derside at the height of the rear axle of the
machine.
2.
Clean the filter. Catch running out deposits in
a suitable container and dispose of.
3.
Screw in the cleaned filter again.
12.1.3 Cleaning the sprayer with
the tank empty
NOTE
The initially forced out residual quantity
is undiluted. Therefore spray the residual
quantity on an untreated surface!
Clean the spraying mixture container after use!
Main cleaning:
1. Empty the solution tank completely.
2.
The fresh water tank must be filled with at
least 300 litres of water.
3. Call up the cleaning menu on the terminal.
4.
Select the "Automatic cleaning" function in
the submenu.
5. Start the program.
¾
When the program is running, the folding
boom, quick filling valve, pressure filter, agita
-
tor and inside tank are cleaned automatically.
¾
The message appears on the terminal
prompting to spray the residual quantity on
an untreated residual area.
¾
CCS cleaning starts.
6. CCS cleaning can be closed manually after
thorough cleaning or it ends automatically
when the fresh water tank contains no more
water.
7.
Spray the residual quantity.
Washing program:
1. Fill the solution tank with approx. 400 l of
water.
2. Call up the cleaning menu on the terminal.
3.
Select the "Washing program" function in the
submenu.
4. Start the program.
5. Activate cleaning of the illuviation valve.
6. Open the switch-over ball valve on the induc-
tion hopper.
7. Switch on canister flushing and operate the
canister flusher using a suitable container,
until only clear water runs out.
8.
Switch on the closed circuit line, until only
clear water runs out
9. Switch on the shock nozzle for approx. 10 sec.
10. Switch on the spray gun and spray into the
tank until only clear water runs out.
11.
Switch off the illuviation valve..
12. Stop cleaning after the desired time.
13. Switch on circulation.
14. Spray the diluted residual quantity on an
untreated residual area.
15.
Activate the "Air Valve" function, in order
to clean the folding boom with air (optional).
16. Repeat steps 1-15 for a second time (if neces-
sary a third time) (dilution principle).
17. Cleaning suction and pressure filters.
NOTE
In multiple nozzle systems all existing nozzles
must be opened for cleaning. There is a risk of
deposits if this instruction is not followed!
160
Содержание LEEB PT 330
Страница 4: ......
Страница 6: ......
Страница 33: ...1 17 Position of safety stickers 33...
Страница 34: ...34...
Страница 173: ...NOTE Lubricate the lubrication points on the folding boom every 50 operating hours or once every week 173...
Страница 187: ...Diagram a with example 187...
Страница 201: ...201...
Страница 202: ......