10.3 Refrigerant
NOTE
The air conditioning system is operated with
the
refrigerant R134a (tetrafluoro-ethane).
This substance does not contain any chlo-
rine atoms and is thus harmless for the
ozone in the atmosphere.
The refrigerant must not simply be drained
off, bust must be professionally disposed
of. Connecting lines must therefore not be
disconnected. Have maintenance and repair
work on the air conditioning system solely
carried out by your HORSCH sales partner
using appropriate disposal and recycling
facilities.
Data sheet refrigerant R 134 a
Refrigerant R 134a
Chemical designation:
1,1,1,2-tetrafluoro-ethane
Chemical formula:
CH2F CF3
Molecular weight:
102.0 g/mol
Boiling point:
(at 1.013 bar) -26.1°C
Freezing point:
-101.0°C
Critical temperature:
-101.1°C
Critical pressure:
40.60 bar
Density (liquid at +25°C)
1206 kg/m
3
Features:
non-toxic, not inflamma
-
ble, inoffensive to ozone
Most important safety
aspect:
suffocating in high
concentrations, can
cause frost injuries
Environmental data HFC 134a
ODP Ozone destruction potential
ODP = 0
CLP Chloride pollution potential
CLP = 0
HGWP Greenhouse effect
HGWP = 0.26
PCR Photo-chemical reactivity
PCR = 0,5
10.4 Collector / dryer
NOTE
The ambient temperature must be higher than
the temperature set on the thermostat (nor-
mally +1 °C) so that the compressor will cut in.
Since the refrigerant collector is under operating
pressure, it is subject to the Pressure Vessel
Ordinance with respect to manufacturing and
testing.
In this ordinance the pressure vessels are clas-
sified in test group II in accordance with their
operating pressure p in bar, their volumetric
capacity l in litres and the pressure contents
product p x l.
According to § 10 of the Pressure Vessel Ordi-
nance, these pressure vessels must be subject-
ed to repetitive testing by an expert as per § 32.
Repetitive tests in this case consist of external
examinations, normally on vessels in opera-
tion. The refrigerant collector is to be visually
examined two times per year in connection with
the inspections. Special attention must thereby
be paid to corrosion and mechanical damage.
Should the tank not be in a fit state, it must be
replaced because of safety related reasons, as
a precautionary measure for the owner and third
parties, because of the dangers related with the
handling and operation of pressure vessels.
Engine area in travel direction left hand side
123
Содержание LEEB PT 330
Страница 4: ......
Страница 6: ......
Страница 33: ...1 17 Position of safety stickers 33...
Страница 34: ...34...
Страница 173: ...NOTE Lubricate the lubrication points on the folding boom every 50 operating hours or once every week 173...
Страница 187: ...Diagram a with example 187...
Страница 201: ...201...
Страница 202: ......