8.6.4 Diluted residual quantities
Perform the dilution and spraying out of residual
quantities from the spraying mixture tank after
the end of spraying operation as follows:
Procedure
1. Spray the undiluted residual quantity from the
spraying line on an untreated residual area.
2. Dilute the residual quantity in the spraying
mixture tank with 200 litres of fresh water.
3. Spray the diluted residual quantity also on an
untreated residual area.
4. Repeat steps 2 and 3 for a second (if neces-
sary a third) time.
Diluting the residual quantity
1. Call up the cleaning menu on the main control
terminal.
2. Select the submenu Dilute the spraying
mixture or recirculate fresh water into the
spraying mixture tank.
3. Select the ratio of fresh water to spraying
mixture.
4. Start the process.
In case of multiple nozzle systems all exist-
ing nozzles must be opened for cleaning.
There is a risk of deposits if this instruction
is not followed!
8.7 Draining the fresh
water tank
Connection of fresh water tank
The port of the fresh water tank is located to the
left of the illuviation valve. It serves to fill the fresh
water tank and to drain the fresh water. Remove
the cap for drainage, open the ball valve and
let the water drain out. Now shut the ball valve
again and close the port with the cap.
WARNING
Danger of poisoning by contaminated water in
the fresh water tank!
Never use the water in the hand washing tank
as drinking water! The materials of the hand
washing tank are not foot compatible.