5.1 -  J1 Wiring Connector:   
 

  Model A Digital Out

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

X 7   M O D E L   A   O N L Y

5.2 - J1 Wiring Connector:   
 

  Model R Relay & Digital Out

NOTE:  Internal 10k

Ω

 resistors 

between:  V+ and Q1; V+ and Q2

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

LOAD

230 VAC or 25 VDC

230 VAC or 25 VDC

230 VAC or 25 VDC

230 VAC or 25 VDC

230 VAC or 25 VDC

230 VAC or 25 VDC

SINKING

SOURCING

X 7   M O D E L   R   O N L Y

X 7   M O D E L S   R   &   A   B O T H

5.4 - J3 Wiring Connector:
 

  RTD Wiring

Primary Power Range:  

24VDC +/- 20%

5.5 - Wiring Connectors:   
 

  Model R & A Power

PIN

4x2-Wire RTD 

Connections

1

AI1

2

RTD1+

3

AI2

4

RTD2+

5

AI3

6

RTD3+/AQ1

7

AI4

8

RTD4+/AQ2

9

Common

       RTD

AI1
R1+

AI2
R2+

AI3

R3+

AQ1

AI4

R4+

AQ2

C

       RTD

       RTD

       RTD

5.3 - J2 Wiring: Model R & A Digital Input

Input 1

Input 2

Input 6
Input 7
Input 8

Input 9   (HSC1)

Input 3

Common

Input 5

Input 4

Input 12 (HSC4)

Input 11  (HSC3)

Input 10 (HSC2)

Common

Содержание X7 OCS

Страница 1: ...ht 100 154mA 24V Power Backlight Off 123mA 24V Inrush Current 30A 1ms Real Time Clock Battery backed lithium coin cell CR2450 Clock Accuracy 90 Secs Month Relative Humidity 5 to 95 Non condensing OperatingTemp 10 C to 60 C Storage Temp 20 C to 70 C Weight 20 8 oz 590 g Included in Box Controller 3 x I 0 connectors 4 x mounting clips 1 x power connector Quick Reference Guide Certifications UL CE US...

Страница 2: ... sure to leave enough room at the top of the unit for insertion and removal of the microSD card 2 Carefully cut the host panel per the diagram on Page 1 creating a 174 63mm x 130 96mm 0 1mm opening into which the X7 may be installed If the opening is too large water may leak into the enclosure potentially damaging the unit If the opening is too small the OCS may not fit through the hole without da...

Страница 3: ...gital Out NOTE Internal 10kΩ resistors between V and Q1 V and Q2 LOAD LOAD LOAD LOAD LOAD LOAD LOAD LOAD 230 VAC or 25 VDC 230 VAC or 25 VDC 230 VAC or 25 VDC 230 VAC or 25 VDC 230 VAC or 25 VDC 230 VAC or 25 VDC SINKING SOURCING X 7 M O D E L R O N LY X 7 M O D E L S R A B O T H 5 4 J3 Wiring Connector RTD Wiring Primary Power Range 24VDC 20 5 5 Wiring Connectors Model R A Power PIN 4x2 Wire RTD ...

Страница 4: ...to the following two conditions 1 This device may not cause harmful interference 2 This device must accept any interference received including interference that may cause undesired operation 6 1 Connecting the X7 to a PC 8 1 Technical Support For further details please refer to the Datasheet MAN1138 For assistance and manual updates contact Technical Support at the following locations North Americ...

Отзывы: