CHAPTER 1:  INTRODUCTION        01 SEPTEMBER 1998                                             PAGE 6

HE500OCS050/051 User Manual

CHAPTER 1:  INTRODUCTION

1.1 Product 

Description

The Horner Electric Operator Control Station (HE500OCS050 or HE500OCS051) combines the
power of a Horner Electric OIU057 (small Operator Interface Unit) with on-board I/O capability
and networking within one controller.

Powerful and compact, the controller has Serial and CAN (Controller Area Network)
communication abilities.  The unit contains a standard 9-pin RS-232 for programming/debugging,
monitoring and network administration from an IBM-compatible PC.  The HE500OCS050 uses
Horner Electric’s CsCAN (pronounced “Sea-scan”) peer to peer networking.  The HE500OCS051
works as a DeviceNet

 slave.  When several Operator Control Stations are networked together

to achieve a specific purpose, the system performs like a “large parallel-processing PLC”.

The Operator Control Station has several desirable features.  The front panel contains a 2x16
Liquid Crystal Display (with backlight), which is highly visible.  The front panel also has five user-
programmable keys, an UP key and a DOWN key.  The bottom of the unit has two Horner Electric
Micro I/O interface ports (for 8 inputs and 8 outputs), DC power port, serial communication and
CAN communication ports.  The controller measures 3.5”x6”x5”x6.”

1.2

Cscape

 Software Package Option

As an option, Horner Electric offers Cscape

  (pronounced “Sea-scape”) Software for use with

the HE500OCS050 and HE500OCS051  .  Powerful yet easy-to-use, the ladder editor
programming software allows for the off-line creation, editing, saving and loading of ladder logic
programs and text screens for the HE500OCS050 and HE500OCS051.  When connected to the
serial port of the Operator Control Station, the software user has the capability to download,
upload, run and monitor ladder programs and text screens.  A comprehensive documentation
package is included with the purchase of Cscape

 Software and contains software, manuals,

and a communication cable.

 

The part number for Cscape Software is HE500OSW232.

F5

F1

F2

F3

F4

 ENTER

Figure 1.1 – Front View

Содержание HE500OCS050

Страница 1: ...User Manual for the HE500OCS050 HE500OCS051 Operator Control Station Third Edition 01 September 1998 MAN0022 03...

Страница 2: ...or otherwise without the prior agreement and written permission of Horner Electric Inc All software described in this document or media is also copyrighted material subject to the terms and conditions...

Страница 3: ...APPLY ONLY WITHIN THE BOUNDARIES OF THE CONTINENTAL UNITED STATES In no event whether as a result of breach of contract warranty tort including negligence or otherwise shall HE or its suppliers be li...

Страница 4: ...are Package Option 6 CHAPTER 2 INSTALLATIONS 8 2 1 Connections 8 2 1 1 General 8 2 1 2 Primary Power Port 8 2 1 3 CAN Port 9 2 1 4 RS 232 Port 10 2 1 5 8 Positive or Negative to Isolated Common Inputs...

Страница 5: ...0 51 This product is NOT to be used in applications where critical control is done based on Network inputs to the unit The integrity of the data being sent to the unit is uncertain in the first 1 10 s...

Страница 6: ...panel contains a 2x16 Liquid Crystal Display with backlight which is highly visible The front panel also has five user programmable keys an UP key and a DOWN key The bottom of the unit has two Horner...

Страница 7: ...s 16 Network Outputs 16 Text Screens 50 User Keys 5 Communications Serial Standard 9 pin RS 232 for programming monitoring and network administration from a IBM compatible PC CAN HE500OCS050 CsCAN pee...

Страница 8: ...ribe each connector 2 1 2 Primary Power Port Table 2 1 Primary Power Port Pins Pin Signal Description 1 V Input power supply voltage 2 V Input power supply ground Note Power Supply Voltage Range is fr...

Страница 9: ...industrial environments and a 3082A thick for environments where noise is a concern 4 The power conductors V and V should be an 18 AWG twisted pair for thin cable and a 15 AWG twisted pair for thick c...

Страница 10: ...r to Send In 8 RTS Request to Send Out 9 RI Always high Out Figure 2 6 CAN Port Wiring Diagram 120 V CN _L SH IEL D CN _H V V CN _L SH IEL D CN _H V V CN _L SH IEL D CN _H V 120 V CN _L SH IEL D CN _H...

Страница 11: ...ectric recommends using a shielded multiple pair wire with a maximum length of 15 meters to ensure maximum performance 2 1 5 8 Positive or Negative to Isolated Common Inputs Input Port Table 2 4 Input...

Страница 12: ...1ms maximum Current Limit 1A typical Protection Inductive clamp diode to isolated supply thermal shutdown Figure 2 9 Input Port As viewed Figure 2 10 Input Port Wiring Diagram looking at the HE500OCS0...

Страница 13: ...oving the four screws holding it in place 3 Insert the OCS through the panel cutout from the front The gasket material should lie between the host panel and the OCS panel 4 Install four hex nuts on th...

Страница 14: ...OCS Rear Cover The steel rear cover provides important protection against RF radio frequency interference d Use a Properly Constructed Communications Cable Great care should be made in the constructio...

Страница 15: ...d in idle mode the flashing character looks like the following When the unit has detected an error while performing a self test it displays this character The unit has been forced into idle mode as we...

Страница 16: ...stics screen as Network Conflicts Failed Note The ID checking works when one of two devices with the same ID is powered up more than 1 second before the other If both devices are powered up at the sam...

Страница 17: ...the following a With DeviceNet nodes 0 63 are available and if the OCS is connected to one HE500OCS051 through serial port it is unable to monitor another OCS on the DeviceNet network b For applicati...

Страница 18: ...he OCS Info screen shows information about the internal state of the unit Pressing and scrolls through the different items Pressing Esc will return to the Main Menu Parameter Description Firmware Show...

Страница 19: ...ta is sent only on change of state b View Registers What the screen display looks like The View Registers screen allows the user to view the state of internal PLC registers Using the and keys the diff...

Страница 20: ...is changed the unit will stop executing the ladder code for up to 10 milliseconds while the setting is saved in non volatile memory g Set Network ID What the screen display looks like In the Set Netw...

Страница 21: ...PAGE 21 01 SEPTEMBER 1998 CHAPTER 3 CONFIGURATION HE500OCS050 051 User Manual...

Отзывы: