TECHNICAL SUPPORT
PRECAUTIONS
All applicable codes and standards need to be followed in the installation
of this product. Adhere to the following safety precautions whenever any
type of connection is made to the module:
1. Connect the safety (earth) ground on the power connector first
before making any other connections.
2. When connecting to the electric circuits or pulse-initiating
equipment, open their related breakers.
3. Do NOT make connection to live power lines.
4. Make connections to the module first; then connect to the circuit
to be monitored.
5. Route power wires in a safe manner in accordance with good
practice and local codes.
6. Wear proper personal protective equipment including safety
glasses and insulated gloves when making connections to power
circuits.
7. Ensure hands, shoes, and floor are dry before making any
connection to a power line.
8. Make sure the unit is turned OFF before making connection to
terminals.
9. Make sure all circuits are de-energized before making
connections.
10. Before each use, inspect all cables for breaks or cracks in the
insulation. Replace immediately if defective.
11. Use copper conductors in Field Wiring only, 60/75
˚
C.
12. Use caution when connecting controllers to PCs via serial or
USB. PCs, especially laptops, may use “floating power supplies:
that are ungrounded. This could cause a damaging voltage
potential between the laptop and controller. Ensure the controller
and laptop are grounded for maximum protection. Consider using
a USB isolator due to voltage potential differences as
a preventative measure.
WARNINGS
1.
To avoid the risk of electric shock or burns, always connect the safety
(or earth) ground before making any other connections.
2. To reduce the risk of fire, electrical shock, or physical injury, it is
strongly recommended to fuse the voltage measurement inputs. Be
sure to locate fuses as close to the source as possible.
3. Replace fuse with the same type and rating to provide protection
against risk of fire and shock hazards.
4. In the event of repeated failure, do NOT replace the fuse again as
repeated failure indicates a defective condition that will NOT clear by
replacing the fuse.
5. Only qualified electrical personnel familiar with the construction
and operation of this equipment and the hazards involved should
install, adjust, operate, or service this equipment. Read and
understand this manual and other applicable manuals in their entirety
before proceeding. Failure to observe this precaution could result in
severe bodily injury or loss of life.
This device complies with part 15 of the FCC Rules. Operation is subject to
the following two conditions:
1. This device may not cause harmful interference
2. This device must accept any interference received, including
interference that may cause undesired operation
FCC COMPLIANCE
These RCC modules are suitable for use in the Class I, Division 2, Groups A, B, C
and D Hazardous Locations only.
WARNING
- EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT
UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE
NON-HAZRDOUS.
ATTENTION
- RISQUE D’EXPLOSION - NE DÉBRANCHEZ PAS L’ÉQUIPEMENT
SAUF SI L’ALIMENTATION A ÉTÉ COUPÉE OU SI LA ZONE N’EST PAS
DANGEREUSE.
Devices shall be installed into an enclosure suitable for the environment that is
only accessible with the use of a tool.
INSTALLATION PROCEDURE
1. The RCC modules conveniently mount on a DIN rail.
2. Be sure the DIN rail is in a horizontal position before installing the unit.
3. The orientation shown to the right is necessary to prevent the unit from
slipping off the DIN rail.
4. Align the unit on the DIN rail then push the DIN rail clip until it clicks into
place. Check to ensure that the unit is secure on the DIN rail.
5. Do NOT mount the unit on its side as this may cause the unit from slipping
off the DIN rail.
NOTE:
The spade connector for grounding and the DIN rail clip add to the
overall measurements. The CAN/PWR and LAN connectors also add to the
measurements.
NOTE:
Screw holes and a spade connector are available for a mounting option.
CONNECTOR
4.57
4.37
2.81
2.13
4.37”
111mm
4.57”
116mm
2.81”
72mm
2.13”
54mm
2.33”
59.25mm
4.67”
118.6mm
4.48”
113.7mm
6. Dimensions
7. Installation Instructions