PRECAUTIONS

All applicable codes and standards need to be followed in the installation 
of this product. Adhere to the following safety precautions whenever any 
type of connection is made to the module:
 

1.  Connect the safety (earth) ground on the power connector first  

 

 

before making any other connections.

 

2.  When connecting to the electric circuits or pulse-initiating  

 

 

 

equipment, open their related breakers.

 

3.  Do NOT make connection to live power lines.

 

4.  Make connections to the module first; then connect to the circuit  

 

 

to be monitored. 

 

5.  Route power wires in a safe manner in accordance with good    

 

 

practice and local codes.

 

6.  Wear proper personal protective equipment including safety    

 

 

glasses and insulated gloves when making connections to power  

   circuits.
 

7.  Ensure hands, shoes, and floor are dry before making any  

 

 

 

connection to a power line.

 

8.  Make sure the unit is turned OFF before making connection to   

   terminals.
 

9.  Make sure all circuits are de-energized before making  

 

   connections.
 

10.  Before each use, inspect all cables for breaks or cracks in the    

 

 

insulation. Replace immediately if defective. 

 

11.  Use copper conductors in Field Wiring only, 60/75

˚

C.

 

12.  Use caution when connecting controllers to PCs via serial or    

 

 

USB. PCs, especially laptops, may use “floating power supplies:  

 

 

that are ungrounded.  This could cause a damaging voltage  

 

 

 

potential between the laptop and controller.  Ensure the controller  

 

 

and laptop are grounded for maximum protection. Consider using  

 

 

a USB isolator due to voltage potential differences as  

 

 

 

a preventative measure.  

WARNINGS

1. 

To avoid the risk of electric shock or burns, always connect the safety  

 

(or earth) ground before making any other connections.

2.   To reduce the risk of fire, electrical shock, or physical injury, it is    
 

strongly recommended to fuse the voltage measurement inputs. Be  

 

sure to locate fuses as close to the source as possible.

3.  Replace fuse with the same type and rating to provide protection    
 

against risk of fire and shock hazards.

4.  In the event of repeated failure, do NOT replace the fuse again as    
 

repeated failure indicates a defective condition that will NOT clear by  

 

replacing the fuse.

5.  Only qualified electrical personnel familiar with the construction    
 

and operation of this equipment and the hazards involved should    

 

install, adjust, operate, or service this equipment. Read and  

 

 

understand this manual and other applicable manuals in their entirety  

 

before proceeding. Failure to observe this precaution could result in  

 

severe bodily injury or loss of life. 

This device complies with part 15 of the FCC Rules. Operation is subject to 
the following two conditions:
 

1.  This device may not cause harmful interference

 

2.  This device must accept any interference received, including    

 

 

interference that may cause undesired operation

FCC COMPLIANCE

These RCC modules are suitable for use in the Class I, Division 2, Groups A, B, C 
and D Hazardous Locations only. 

WARNING 

- EXPLOSION HAZARD - DO NOT DISCONNECT EQUIPMENT 

UNLESS POWER HAS BEEN SWITCHED OFF OR THE AREA IS KNOWN TO BE 
NON-HAZRDOUS. 

ATTENTION

 - RISQUE D’EXPLOSION - NE DÉBRANCHEZ PAS L’ÉQUIPEMENT 

SAUF SI L’ALIMENTATION A ÉTÉ COUPÉE OU SI LA ZONE N’EST PAS 
DANGEREUSE.

Devices shall be installed into an enclosure suitable for the environment that is 
only accessible with the use of a tool.

INSTALLATION PROCEDURE

1.  The RCC modules conveniently mount on a DIN rail. 
2.  Be sure the DIN rail is in a horizontal position before installing the unit. 
3.  The orientation shown to the right is necessary to prevent the unit from  
 

slipping off the DIN rail.  

4.  Align the unit on the DIN rail then push the DIN rail clip  until it clicks into  
 

place. Check to ensure that the unit is secure on the DIN rail. 

5.   Do NOT mount the unit on its side as this may cause the unit from slipping  
 

off the DIN rail. 

NOTE:

 The spade connector for grounding and the DIN rail clip add to the 

overall measurements. The CAN/PWR and LAN connectors also add to the 
measurements. 

NOTE:

 Screw holes and a spade connector are available for a mounting option. 

CONNECTOR

4.57

4.37

2.81

2.13

4.37”

111mm

4.57”

116mm

2.81”

72mm

 2.13”

54mm

2.33”

59.25mm

4.67”

118.6mm

4.48” 

113.7mm

6. Dimensions

7. Installation Instructions

Содержание HE-RCC1410

Страница 1: ...4VDC switched Primary Power Range RCC972 10 32VDC RCC1410 10 32VDC RCC2414 10 28VDC RCC8842 10 32VDC Relative Humidity 5 to 95 Non condensing OperatingTemp 10 C to 60 C Storage Temp 20 C to 70 C Weight 10 oz 283 5g Certifications CE USA https hornerautomation com certifications Europe https www hornerautomation eu support certifications 2 RCC Real Time Clock DC In 12 24VAC DC Out 24VDC Analog In 0...

Страница 2: ...4 Digital In4 I3 Digital In3 I2 Digital In2 I1 Digital In1 AI1 AI2 AI3 AI4 AI5 AI6 AI7 AI8 C AQ1 AQ2 AQ3 AQ4 C CH CL LOOP PWR CAN High CAN Low 20mA 0 20mA TRANSMITTER Analog I O 1 Analog In1 2 Analog In2 3 Analog In3 4 Analog In4 5 Analog In5 6 Analog In6 7 Analog In7 8 Analog In8 C OV 1 Analog Out1 2 Analog Out2 3 Analog Out3 4 Analog Out4 OV OV CH CAN High CL CAN Low Power Wiring To power up the...

Страница 3: ... power up the RCC8842 supply 10 32VDC to the V and V connections on the Power CAN and Analog Connector 1 2 V Digital Output Wiring V 1 2 3 4 V2 10 24VDC HE RCC8842 8 Digital Inputs 8 Digital Outputs 4 Analog Inputs 2 Analog Outputs Digital Input Wiring V V on top connector on top connector Digital Output Wiring Analog Input Wiring CAN PWR AND ANALOG I O CONNECTOR 9 10 11 V SENSOR SENSOR 0 10V Loop...

Страница 4: ... To reduce the risk of fire electrical shock or physical injury it is strongly recommended to fuse the voltage measurement inputs Be sure to locate fuses as close to the source as possible 3 Replace fuse with the same type and rating to provide protection against risk of fire and shock hazards 4 In the event of repeated failure do NOT replace the fuse again as repeated failure indicates a defectiv...

Отзывы: