4
CHAPTER 2: Engineering Mode
2.1 ENGINEERING MODE
1) To enter Engineering Mode, press & hold the INCLINE
UP
“
▲
”
and SPEED DOWN
“
-
-
-
-
”
keys at the same time
for 3-5 seconds until Engineering Menu appears on the
display.
2) Use the INCLINE and SPEED UP and DOWN keys to
select a parameter.
3) Press ENTER to enter a parameter setting.
4) Use the INCLINE and SPEED UP and DOWN keys to
change the parameter.
5) Press the START key to save the change to the parameter.
6) Press and hold the STOP key to exit Engineering Mode and return to normal operation.
MODE
FUNCTION
DESCRIPTION
ENG 0 Display Test
Start Key – LCD/LED on
Stop Key – LCD/LED off
Any Other Key - Will show on the display window.
Hold the STOP key for 3 seconds to return to the Engineering Menu.
ENG 1 Hardware Test
Motor & Incline Motor Test.
ENG 2 Auto Calibration
Auto calibrates the speed only.
ENG 3 Manual Calibration To setup speed by manual (see flow chart as below)
P1: Low speed
P2: Low-Mid speed
P3: Mid speed
P4: Mid-High speed
P5: High Speed
.
ENG 4 Roller diameter
switch
Roller diameter adjustment to match up real speed
UP key: +1
FAST key: +10
DOWN key: -1
SLOW key: +10
Hold START key 3sec to save parameter
Содержание T4000 Premier
Страница 1: ...1 T4000 Premier TM219B SERVICE MANUAL...
Страница 3: ...3 CHAPTER 1 Serial Number Location The serial number is located on the front tube of frame...
Страница 5: ...5...