15
CHAPTER 5:TROUBLESHOOTING
5.5 RESISTANCE ISSUE
Symptom:
No resistance or incorrect resistance
Solution:
1. Turn on the console and check the ECB motor (1000213379)/tension control (1000412305).
At resistance level 1, the head of steel rope directs to top right side (around 45 degree).
If the head of steel rope points to bottom left side, the resistance will be reverse. Adjust the head of steel
rope to the correct position.
Notes: in the lowest resistance level, the cable should have no tension.
2. Use knob to adjust the resistance.
A)
If ECB motor/tension control cannot move,
the resistance will not be changed. The ECB motor
or console cable is defective. Check the console cable inserted in ECB motor. Re-connect the console
cable first, if still not working, test cable for damage. If tests good, replace the ECB motor, make sure
both cable ends are seated properly.