FIVE-STEP DIAGNOSIS PROCESS - Continued
2. Proper
Wiring
- Verify that all wires are secure and attached in the correct position (reference
wiring diagrams in table of contents).
- Verify that there aren’t any pinches or cuts in any of the wires, especially the
console cable connecting from the lower board to the upper board. Replace
and wires that are pinched or cut.
3. Proper Sensor Wire Function
- Verify that the rpm sensor wire is positioned as close to the front roller
pulley as possible. The factory standard is a distance or 2-4 mm between
the sensor wire and the front roller pulley. Loosen the sensor bracket
attachment screws and position sensor bracket closer to front roller pulley if
the distance is greater than 2-4 mm.
- Verify that the sensor wire is attached to the sensor bracket properly. The
proper position would be so that the sensor wire is protruding from the left
hand side of the sensor and sensor bracket while facing the treadmill.
- Verify that the rpm magnet is positioned in the front roller pulley.