background image

EDUSTAK JUNIOR

Build

 

Yourself

 

Fuel

 

Cell

 

Stack

 

Kit

 

– FCSU

32

User Manual

User Manual

EDUSTAK

 

JUNIOR

 

User

 

Manual

 

rev.1.1

©2013

 

Horizon

 

Ltd.

 

All

 

rights

 

reserved.

Содержание EDUSTAK JUNIOR

Страница 1: ...EDUSTAK JUNIOR Build Yourself Fuel Cell Stack Kit FCSU 32 User Manual User Manual EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd All rights reserved...

Страница 2: ...lists 2 3 3 Part lists 4 EDUSTAK JUNIOR specifications 5 Operation guide 5 6 7 p g 6 Disassembly guide 7 Assembly guide 7 13 16 8 Leakage testing 9 FAQ 23 27 10 Troubleshooting 31 1 EDUSTAK JUNIOR Use...

Страница 3: ...ely void any warranty on the system Misuse neglect or improper servicing of this equipment may result in the kit damage Do not operate this kit if it is damaged Failure to observe instructions contain...

Страница 4: ...USTAK JUNIOR or its fuel cartridge Protect from heat and ignition sources Hydrogen is highly flammable sources Hydrogen is highly flammable After an accident or in the event of damage to the fuel cart...

Страница 5: ...ance to not vent freely Keep away from alkaline and acidic environment This is not toy keep away from children The HYDROSTIK PRO cartridge must be placed horizontally when it is being charged otherwis...

Страница 6: ...amp with tube m Pressure regulator n HYDROSTIK PRO support o Wires e f g h i j k l m n o The EDUSTAK JUNIOR is already assembled when you receive it for the first time The HYDROSTIK PRO contains no hy...

Страница 7: ...ling Air integrated cooling fan Cooling Air integrated cooling fan Dimension 125mm 60mm 95mm Weight 510 g Flow rate at max output 0 05 L min Start up time 30S at ambient temperature Efficiency of stac...

Страница 8: ...erature Keep it away from the strong direct sunlight Manually use the purging valve to purge the system every 3 minutes for good performance EDUSTAK JUNIOR is not a cell phone charger but it could be...

Страница 9: ...mbled when you receive it for the first time which could be directly tested Step 1 Clips the EDUSTAK JUNIOR and the electronic PCB card directly together Ensure the connection in the good sense electr...

Страница 10: ...he pressure regulator Do the same operation between the other end of the tube and the upper nozzle of the EDUSTAK JUNIOR close to the PCB card Step 3 Unscrew the lower nozzle bolt and pass it around t...

Страница 11: ...IK PRO onto its support and lightly screw the pressure regulator onto the HYDROSTIK PRO nozzle Stop to screw it as soon as both part meet together On the opposite the hydrogen will go out of the HYDRO...

Страница 12: ...p 6 Connect the crocodiles pincers to the blower fan wires Ensure to respect the polarity shown by the color code Now your system is ready to work EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd A...

Страница 13: ...7 Finish to screw the pressure regulator to the HYDROSTIK PRO As soon as it will be done the blower fan will start and the LEDs on it will light on EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd...

Страница 14: ...ew the right closest corner wing nut 1 only on the half of the available length Do the same with the left opposite 2 corner wing nut then with the closest left one and finish by the bottom right corne...

Страница 15: ...6 Disassembly Guide Step 2 Hang the system and remove the long screw from their position Your cell is disassembled EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd All rights reserved 14...

Страница 16: ...plate b Low end plate c Single cell 10pcs a c d b c Single cell 10pcs d Sealing 11pcs e Plastic plate 11pcs f Plastic cell g Screw rods h Wing nuts i Washers j Bolts e f g h i j Note For any manipulat...

Страница 17: ...guide Tools maybe needed during the assembly Step 1 Pass the screw rods through the basis of the low end plate Return the basis and put it on a plane area Note Pay close attention to the direction of...

Страница 18: ...downwards on the screw and ensure the grooves are putted on the upper side Note Pay close attention to the and on the plastic plate Make sure all the plastic plate should face the same direction Seal...

Страница 19: ...rresponding groove and ensure it is deeply inserted Note Pay close attention to the direction of the rubber seal The round side of the rubber seal should be facing upwards g p EDUSTAK JUNIOR User Manu...

Страница 20: ...les are on the upper side Note Pay close attention to the direction of the single cell Ensure to put the two ends of the cell in the same side than the side of the plastic plate without the raised edg...

Страница 21: ...ssembly Guide Step 5 Restart at step two with all the remaining plates cells and seals Make sure all parts direction are correct EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd All rights reserved...

Страница 22: ...Put the plastic cell with the sealing facing upwards on the top and ensure the whole on it is faced to the corresponding one on the previous plate EDUSTAK JUNIOR User Manual rev 1 1 2013 Horizon Ltd...

Страница 23: ...per end plate You can notice on the upper end plate it also marks and Make sure they are facing the same direction as the plastic plate y g p p 2 After assembly measure the length between the upper en...

Страница 24: ...ng Valve with tube a b c g g e Three port connector f 2 silicon tubes a b g Clamp with tube d e f Note After assembling the product you have to do the leakage testing before any use THIS STEP IS VERY...

Страница 25: ...e clamp bigger diameter to the three way port Step 2 Connect the other side of the clamp tube with the air pressure bulb Ensure all the connections are tight Step 3 Connect a free ends of one of the l...

Страница 26: ...the same with the purging valve tube and the remaining nozzle Step 5 Turn the switch slowly on the air pressure bulb in clockwise until it can t be turned anymore Step 5 Turn the switch slowly on the...

Страница 27: ...ckly please re assemble the EDUSTAK JUNIOR and h k th f ll i thi f ll check the following things carefully 1 If the single cells have been installed in the right direction 2 If the rubber sealing has...

Страница 28: ...stigate MEAs behavior Q How does EDUSTAK JUNIOR work A After the stack has been assembled and leakage checking has been done connect the hydrogen supply purging g g y g pp y p g g valve and load etc M...

Страница 29: ...ly assembled and dismantled by the user We believe it s the best way to understand how a fuel cell really works y y Q What is a HYDROSTIK PRO and what is it used for A HYDROSTIK cartridges store energ...

Страница 30: ...our technology a sealing border which allows the separation of Membrane Electrode Assemblies MEAs or the fuel cells from the bipolar conductive plates Q How can I replace the single cells A If a singl...

Страница 31: ...nce a week and control it based on the temperature curve Q What are the refill options for HYDROSTIK PRO cartridges A 1 HYDROSTIKs can be recharged using Horizon s HYDROFILL PRO cartridge refilling so...

Страница 32: ...xchange membrane in the EDUSTAK JUNIOR The PEM is moistened automatically during operation This may take up to 5 minutes 2 The EDUSTAK JUNIOR leakages after assembly Solution Check the following parts...

Страница 33: ...kly after the clamp has been closed please re assemble the EDUSTAK JUNIOR and check the following things carefully 1 If the single cells have been installed in the right direction 2 If the rubber seal...

Отзывы: