R
EMOTE
S
OFTWARE
6021GPS GPS Satellite Clock - V01.00
29 / 41
hopf
Elektronik GmbH
Nottebohmstr. 41 • D-58511 Lüdenscheid • Tel.: +49 (0)2351 9386-86 • Fax: +49 (0)2351 9386-93 • Internet: http://www.hopf.com • E-Mail: [email protected]
3.9.1.9 Delayed Transmission
The last character of the data string is transmitted directly at the second change and
immediately thereafter the new data string, which is valid for the next second change, is
transmitted with the setting
"<etx> at second change"
. This can be interpreted as an error
on some computers with a high working load. With function
"with delay"
, transmission of the
new data string can be delayed dependent on the baud rate.
Example:
Baud rate 9600 baud
Milliseconds With
delay Without
delay
000
End character ( ETX)
End character ( ETX)
002
–
New data string
025
–
End new data string
930
New data string
–
955
End new data string
–
000
End character (ETX)
End character (ETX)
Baud rate 2400 baud
Milliseconds With
delay Without
delay
000
End character ( ETX)
End character ( ETX)
002
–
New data string
105
–
End new data string
810
New data string
–
913
End new data string
–
000
End character (ETX)
End character (ETX)
3.9.1.10 Send Cycle
Send Cycle
every second
every minute
every hour
on request only
3.9.1.11 Change of <CR> <==> <LF> -
<CR> <= => <LF>
<CR><LF>
<LF><CR>