3
• Position machine within two feet of inlet. Use Front
End Guide Hose when it is difficult to locate the
machine near the access or clean out. Greater
distances can result in cable twisting or kinking.
• Do not operate machine in (REV) reverse.
Operating machine in reverse can result in cable
damage and is used only to back tool out of an
obstruction.
• Be careful when cleaning drains where cleaning
compounds have been used. Avoid direct contact
with skin and eyes. Serious burns can result from
some drain cleaning compounds.
• Do not operate machine if operator or machine is
standing in water. Will increase the risk of electrical
shock.
• Wear safety glasses and rubber soled, non-slip
shoes. Use of this safety equipment may prevent
serious injury.
• Only use the A200 to clean drain lines up to 8″ in
diameter. Follow instructions on the use of the
machine. Other uses or modifying the drain cleaner
for other applications may increase the risk of injury.
Description, Specifications and
Standard Equipment
Description
The A200 is a portable Drain Cleaning Machine
designed to clean 2” to 8” drain lines. Applications
include sink, shower and floor drains. Capable of
running 1 size cables: 32mm.
The machine is driven by a 900W motor that has a
grounded electrical system. A toggle switch provides
FORWARD/OFF/REVERSE control of the motor.
The A200 is designed to use 1 1/4”(32mm)
diameter sectional-type cable that has a quick
change coupling system for disconnecting tools. The
cable is manually fed in and out of the drain and
rotates at a speed of 460 RPM. The rotation of the
cable is controlled by a clutch handle. The cable
stops instantly when the clutch handle is released.
Specifications
cable.
Cable Sizes ..................32mm
Motor Type ..............................115V/50-60 Hz,
Reversible, 230V Available Upon Request
Rating ............................900W (input 1400W)
Weight...........................GW/NW:86/80KG
Dimensions
Length ........................... 895mm
Height ............................590mm
Width ............................. 680mm
Machine Inspection
To prevent serious injury, inspect your Drain Cleaning
Machine. The following inspection procedures should be
performed before each use.
1. Make sure the Drain Cleaning Machine is
unplugged and the directional switch is set to the
OFF position.(Figure 1)
Left: to reverse
Middle: to stop
Right: to forward
Fig 1
Содержание A200
Страница 9: ...8 ...