background image

 

direct contact with skin and eyes. Serious burns 

can result from some drain cleaning compounds. 
• Do not operate machine if operator or machine 

is  standing  in  water.  Will  increase  the  risk  of 

electrical shock. 
• Wear safety glasses and rubber soled, non-slip 

shoes. Use of this safety equipment may prevent 

serious injury. 
• Only use the A150 to clean drain lines up to 6″ 

in diameter. Follow instructions on the use of the 

machine.  Other  uses  or  modifying  the  drain 

cleaner  for  other  applications  may  increase  the 

risk of injury. 

 

Description, Specifications and 

Standard Equipment 

Description 

The A150 is a portable Drain Cleaning Machine 

designed  to  clean  11/4

”  to  6”  drain  lines. 

Applications  include  sink,  shower  and  floor 

drains. Capable of running 2 different size cables: 

16mm and 22mm. 

The machine is driven by a 750W motor that has 

a  grounded  electrical  system.  A  toggle  switch 

provides  FORWARD/OFF/REVERSE  control  of 

the motor. 

The  A150  is  designed  to  use  5/8

”(16mm)  and 

7/8

”(22mm)  diameter  sectional-type  cable  that 

has  a  quick  change  coupling  system  for 

disconnecting tools. The cable is manually fed in 

and  out  of  the  drain  and  rotates  at  a  speed  of 

460 RPM. The rotation of the cable is controlled 

by  a  clutch  handle.  The  cable  stops  instantly 

when the clutch handle is released. 

The  A150  is  also  designed  to  use  with  the 

adapter  (optional)  which  hold  5/16

”(8mm) 

continuous  length  cables.  Rotation  of  the 

adapter  is  controlled  by  the  clutch  handle.  The 

cable  adapter  is  equipped  with  a  quick-acting 

brake  which  immediately  stops  rotation  of  the 

drum when the clutch handle is pulled upward. 

 

Specifications 

Line  Capacity  ...............Depends  on  choice  of 

cable. 

Cable Sizes ..................16mm, 22mm 

Motor  Type  ..............................115V/50-60  Hz, 

Reversible, 230V Available Upon Request 

Rating ............................750W (input 1100W) 

Amps .............................5.5A/10A 

Weight...........................22.5KG 

Dimensions 

Length ........................... 455mm 

Height ............................525mm 

Width ............................. 250mm 

 

Machine Inspection 

To  prevent  serious  injury,  inspect  your  Drain 

Cleaning  Machine.  The  following  inspection 

procedures should be performed before each use. 

1.  Make  sure  the  Drain  Cleaning  Machine  is 

unplugged and the directional switch is set to the 

OFF 

position.(Figure 1) 

Left: to reverse

 

 

Middle: to stop

 

 

Right: to forward

 

Fig 1 

 

2. Inspect the power cord and plug for damage. 

If  the  plug  has  been  modified,  is  missing  the 

grounding  prong  or  if  the  cord  is  damaged,  do 

not  use  the  Drain  Cleaning  Machine  until  the 

cord has been replaced. 

Содержание A150

Страница 1: ...ng Machine Operation Manual WARNING Read this Operator s Manual carefully before using this tool Failure to understand and follow the contents of this manual may result in electrical shock fire and or serious personal injury ...

Страница 2: ...rease the risk of electrical shock When operating a tool outside use an outdoor extension cord marked W A or W These cords are rated for outdoor use and reduce the risk of electrical shock Use only three wire extension cords which have three prong grounding plugs and three pole receptacles which accept the tool s plug Use of other extension cords will not ground the tool and increase the risk of e...

Страница 3: ...idents are caused by poorly maintained tools Use only accessories that are recommended by the manufacturer for your model Accessories that may be suitable for one tool may become hazardous when used on another tool Keep handles dry and clean free from oil and grease Allows for better control of the tool Service Tool service must be performed only by qualified repair personnel Service or maintenanc...

Страница 4: ...e is manually fed in and out of the drain and rotates at a speed of 460 RPM The rotation of the cable is controlled by a clutch handle The cable stops instantly when the clutch handle is released The A150 is also designed to use with the adapter optional which hold 5 16 8mm continuous length cables Rotation of the adapter is controlled by the clutch handle The cable adapter is equipped with a quic...

Страница 5: ... serious injury Machine Set Up WARNING Do not place machine in water Water entering the motor can result in electrical shock To prevent serious injury proper set up of the machine and work area is required The following procedures should be followed to set up the machine Set Up For 5 8 16mm Sectional Cable 1 Check work area for Adequate lighting Grounded electrical outlet Clear path to the electri...

Страница 6: ...ING Wear mitts with rivets provided with machine Never grasp a rotating cable with a rag loose fitting cloth or leather glove that may become wrapped around the cable causing serious injury Always wear eye protection to protect your eyes against dirt and other foreign objects Wear rubber soled non slip shoes Be very careful when cleaning drains where cleaning compounds have been used Wear gloves w...

Страница 7: ...sharpness of the tool and nature of the obstruction WARNING Do not allow tension to build up in the cable This will happen if the cutting tool hits a snag and stops turning but the motor and cable continue to rotate Torque builds until the cable suddenly twists potentially wrapping around your hand or arm This can happen quickly and without warning so proceed slowly and carefully as you feed the c...

Страница 8: ...to insert into the drain opening and hand feed the cable into drain until it stops feeding easily Push cable down drain line keeping your control hand close to the drain opening 3 Hold cable loosely in mittened hand put FOR OFF REV SWITCH in FOR forward position NOTE The motor will start but cable will not rotate 4 With mitted hand on cable push down on clutch handle with opposite hand to engage a...

Страница 9: ...n cleaning compounds Periodically lubricate cables and couplings When not in use store cables indoors to prevent deterioration by the elements Cables should be replaced when they become severely corroded or worn A worn cable can be identified when outside of coils become flat Cable Containers Cable container on 5 16 cable adapter optional should be periodically cleaned 1 Remove cable from the cabl...

Отзывы: