XNX Universal Transmitter
Specifications
143
EC Sensor Performance Data, DEKRA EXAM Verified
Certifications by Part Number Series
)
Gas
Cartridge
Part Number
Selectable Full
Scale Range (Dis-
play and 4-20mA
Full Scale)
Default
Range
Range
Incre-
ments
Lower
Alarm
Limit
Lower
Detection
Limit
Zero
Variation
Selectable
Cal Gas
Range
Default
Cal Point
Response
Time (T50)
(sec)
T90 Response
T10 Recovery
Time (sec)
Accuracy1
Operating Temperature
Operating Humidity
EC Sensor
Expected
LIfe
(months)
Min
Max
Min
Max
O
2
Oxygen
XNXXSO1SS
n/a
25.0 %Vol
n/a
5.0%Vol
3.5 %Vol
n/a
20.9 %Vol
(fixed)
20.9 %Vol
T20 <10
<30
<+/-0.6 %Vol
-30°C / -34°F
55°C /131°F
15% RH
90% RH
24
H
2
S
Hydrogen
Sulfide
XNXXSH1SS
10.0 to 50.0 ppm
15.0 ppm
0.1ppm
3.0 ppm
1.0 ppm
2.0 ppm
30 to 70%
of the
selected full
scale range
10 ppm
<20
<30
<+/-0.3 ppm
-40°C / -40°F
55°C / 131°F
15% RH
90% RH
12
H
2
S (High)
Hydrogen
Sulfide
XNXXSH2SS
50 to 500 ppm
100 ppm
10 ppm
5 ppm
1 ppm
2 ppm
50 ppm
<20
<30
<+/-5 ppm
-40°C / -40°F
55°C / 131°F
15% RH
90% RH
12
CO
Carbon
Monoxide
XNXXSC1SS
100 to 500 ppm
300 ppm 100 ppm
15 ppm
5 ppm
10 ppm
100 ppm
<15
<30
<+/-2 ppm
-40°C / -40°F
55°C / 131°F
15% RH
90% RH
24
Footnote:
1. Accuracy of reading at default Alarm 1 concentration (typically 10% FS or defined minimum alarm level setting, whichever is greater) when operated at default full scale.
Notes:
•
Sensor drift between LDL and negative drift fault limits (typcially > negative zero variation) appear as 0 on the display and outputs of the device.
•
Long-term drift: XNXXSC1SS <5%/year, XNXXSO1SS <4%/year, XNXXSH1SS and XNXXSH2SS <2%/month.
•
Performance figures are measured by test units calibrated at 50% of full scale, at ambient conditions of 20°C, 50% RH, with the EC weatherproof cover attached.
•
Operating the EC sensor at extended temperature ranges for a prolonged time period exceeding 12 hours may cause deterioration in sensor performance and shorten sensor
life. Extended temperature ranges for XNX EC sensor cartridges are -40°C to -20°C.
• Barometric
pressure effects on the O
2
sensor: The output from the O
2
sensor has pressure effects of <0.1% change of output per % change in pressure. When the barometric
pressure changes by ±20%, the output from the O
2
sensor changes <±0.4%Vol. However, the oxygen sensor shows transient behavior when subjected to a rapid change in
ambient pressure due to either weather or altitude. For example, a 10KPa instantaneous positive pressure step change may cause an overscale alarm condition for a period
of about 12 seconds.
•
Response times may increase at lower temperatures.
•
Contact Honeywell Analytics for any additional data or details.
Содержание XNX-AM Series
Страница 2: ...This page is intentionally left blank ...
Страница 7: ...XNX Universal Transmitter Safety and Information 5 Safety and Information ...
Страница 12: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 10 Introduction ...
Страница 27: ...XNX Universal Transmitter Introduction 25 Menu Navigation ...
Страница 31: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 29 Installation and Operation ...
Страница 102: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 100 Calibration ...
Страница 118: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 116 Maintenance ...
Страница 122: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 120 Warnings and Faults ...
Страница 139: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 137 Specifications ...
Страница 174: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 172 Control Drawings ...
Страница 177: ...XNX Universal Transmitter Control Drawings 175 ...
Страница 179: ...XNX Universal Transmitter Control Drawings 177 Remote Sensor Mount ...
Страница 180: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 178 HART Protocol ...
Страница 193: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 191 Modbus Protocol ...
Страница 200: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 198 Warranty ...
Страница 202: ...XNX Universal Transmitter XNX Universal Transmitter Technical Manual 200 Index ...
Страница 206: ...This page is intentionally left blank ...