background image

X-XX UL

INSTALLATION INSTRUCTIONS

®U.S. Registered Trademark
Copyright © 1998 Honeywell Inc.  •   All Rights Reserved

W8600F

 Air Cleaner Monitor

APPLICATION

The W8600F Air Cleaner Monitor is an option available for
use with the F50F and F52F Honeywell Electronic Air
Cleaners (EAC). The series two F50F and F52F require a
solid state power supply that is compatible with the
W8600F driver board. Any series one F50E, F or F52F
can be upgraded to use the W8600F when the power
supply is replaced and the driver board (included in
W8600F kit) is installed.

The W8600F function indicator panel has four liquid crystal
display (LCD) arrowheads that point to ON, BATTERY,
SERVICE or FAULT. See Fig. 1. The arrowheads darken
to indicate the existing EAC condition. See Table 1.

INSTALLATION

When Installing this Product..

1. Read these instructions carefully. Failure to follow

the instructions could damage the product or cause
a hazardous condition.

2. Check the ratings given in the instructions and on

the product to make sure the product is suitable for
your application

3. Installer must be a trained, experienced service

technician.

4. After completing the installation, use these instruc-

tions to check out the product operation.

Location

The styling of the W8600F is designed to blend with the
latest T8600 family of Honeywell Chronotherm® IV Deluxe
Programmable Thermostats. A special mounting template
is included for mounting next to the T8600. The W8600F
can also be mounted at any other convenient location in
the living area or equipment room. See Fig. 2.

NOTE:

The W8600F shares no common electrical
connections with the thermostat.

Indicators

Condition

ON

EAC is powered and system blower is
running.

BATTERY

Battery that maintains W8600F memory
is low and needs to be replaced.

SERVICE

EAC prefilter and cells need to be
washed

a.

FAULT

Shorting of collector plates.

Continuous ionizer or collector plate
arcing.

Power supply failure.

Excessive current.

Major reduction in high voltage.

EAC prefilter and cells are past
SERVICE level of dirt and need to be
washed immediately.

Call a service technician.

Fig. 1. W8600F Air Cleaner Monitor features.

Table 1.Description of W8600F

Function Indicator Panel.

ON

BATTERY

SERVICE

FAULT

Air  Cleaner  Monitor

FUNCTION
INDICATOR
PANEL

LCD

RESET BUTTON

M11965

a

The reset button is located on the bottom of W8600F.
After the prefilters and cells are cleaned and reinstalled,
press this button to turn off the SERVICE indicator and
reset the wash frequency timer.

69-1200-1

Содержание W8600B

Страница 1: ...tion use these instruc tions to check out the product operation Location The styling of the W8600F is designed to blend with the latest T8600 family of Honeywell Chronotherm IV Deluxe Programmable Thermostats A special mounting template is included for mounting next to the T8600 The W8600F can also be mounted at any other convenient location in the living area or equipment room See Fig 2 NOTE The ...

Страница 2: ...he screw anchors and the 3 conductor thermostat cable 3 Remove the template and drill the holes 4 Remove the W8600F from the base 5 Position the W8600F base over the holes and install the anchors and screws included in the bag assembly Tighten the screws until the base is mounted firmly on the wall Fig 3 Positioning mounting template W8600F W8600F W8600F W8600F W8600F EAC EAC EAC EAC EAC M11966 RE...

Страница 3: ...rn off the power for the EAC WARNING Electric Shock Hazard Can cause electrical shock or equipment damage Disconnect EAC power and open the access door before opening the power supply box cover 6 Open the power supply box cover 7 Remove the plug from the side of the power supply box plug can be a metal knockout or a blank terminal strip 8 Install the terminal block cable assembly supplied with W86...

Страница 4: ...put The W8600 is functional TROUBLESHOOTING Refer to Table 3 Table 3 W8600F Troubleshooting Information Display Condition Solution Blank EAC is not operating Turn on EAC Function panel indicates ON Press W8600F reset button DISPLAY flashes five times ON indicator does not flash when reset button is pressed Check W8600F battery for 2 7 volts Replace with BR2032 lithium battery if necessary All four...