172
Voyager 1470/1472 User Guide
scanner is Voyager_1472 scanner. This setting is changed by using
the BT_NAM command, which accepts alphanumeric values. If the
name is not known, a wildcard (*) can be used :*:.
Note:
Since the base stores all work group settings and transfers to them to scanner once
they are linked, changes are typically done to the base and not to the scanner.
Tag
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS232 configuration settings are
identified with a Tag of
232
.
SubTag
A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS232 baud rate is
BAD
.
Data
The new value for a menu setting, identified by the Tag and SubTag.
Storage
A single character that specifies the storage table to which the com-
mand is applied. An exclamation point (!) performs the command’s
operation on the device’s volatile menu configuration table. A period
(.) performs the command’s operation on the device’s non-volatile
menu configuration table. Use the non-volatile table only for semi-
permanent changes you want saved through a power cycle.
Query Commands
Several special characters can be used to query the device about its settings.
^
What is the default value for the setting(s).
?
What is the device’s current value for the setting(s).
*
What is the range of possible values for the setting(s). (The device’s
response uses a dash (-) to indicate a continuous range of values. A
pipe (|) separates items in a list of non-continuous values.)
:Name: Field Usage (Optional)
This command returns the query information from the scanner.
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the
entire
set of
commands available for the particular storage table indicated by the Storage field
of the command. In this case, the SubTag and Data fields should not be used
because they are ignored by the device.
Содержание Voyager XP 1470
Страница 1: ...User Guide Voyager XP 1470g 1472g Series Area Imaging Scanner ...
Страница 14: ...xii Voyager 1470 1472 User Guide ...
Страница 16: ...xiv Voyager 1470 1472 User Guide ...
Страница 26: ...10 Voyager 1470 1472 User Guide ...
Страница 47: ...Voyager 1470 1472 User Guide 31 300 600 1200 2400 4800 9600 19200 38400 57 600 115 200 ...
Страница 128: ...112 Voyager 1470 1472 User Guide Data Format 1 Data Format 2 Data Format 3 ...
Страница 182: ...166 Voyager 1470 1472 User Guide ...
Страница 222: ...206 Voyager 1470 1472 User Guide ...
Страница 228: ...212 Voyager 1470 1472 User Guide ...
Страница 240: ...224 Voyager 1470 1472 User Guide ...
Страница 243: ...Voyager 1470 1472 User Guide 227 PROGRAMMING CHART 0 1 2 3 4 5 6 7 8 9 ...
Страница 245: ......
Страница 246: ... Honeywell 9680 Old Bailes Road Fort Mill SC 29707 www honeywellaidc com VG147X UG 01 Rev A 5 19 ...