V5097A-E INDUSTRIAL GAS VALVES

5

65-0230—07

Fig. 2. Approximate dimensions of two small and large V5097 Valves with valve 

actuators and pipe adapters in inches and millimeters.

Table 3. V5097 Models.

a

Maximum operating pressure differential. Once open, the valve and actuator operate correctly against this pressure differential at 

85% of rated voltage.

b

Maximum opening pressure. Actuator opens valve against this pressure at 85% of rated voltage.

c Maximum close-off pressure. Maximum allowable pressure drop across fully closed valve prevents seal leakage (independent of 

75 psi valve body rating).

Model

Pipe Size 

(in. NPT)

Standard Pressure Actuators

V4055A,D, V4062, V9055

High Pressure Actuators

V4055B,E

MOPD

a

MOP

b

MCOP

c

MOPD

a

MOP

b

MCOP

c

psi

mbar

psi

mbar psi bar

psi

bar

psi

bar

psi

bar

Standard Pressure Valves 

V5097A,B,C

3/4 to 2

5

340

15

1000 15

1

15

1

15

1

15

1

2 to 3

13

880

High Pressure Valves 

V5097D,E

3/4 to 2

5

340

40 

2700 75

5

25

1.6

62

4

75

5

2 to 3

13

880

45

3

15

1

21

1.4

45

3

6-3/4 (171)

1-9/32

(33)

D

DIM. A

DIM. B

DIM. C

DIM. D

DIM. E

DIM. F

DIM. G

DIM. H

DIM. J

G

E

C

A

H

F

J

OCTAGON

OCTAGON

5 (127)

VALVE

SIZE

(IN.)

IN.       MM

IN.       MM

IN.       MM

IN.       MM

IN.       MM

IN.       MM

IN.       MM

11-1/8
11-1/8
11-1/8
11-1/8
11-3/4
11-3/4
11-3/4

283
283
283
283
298
298
298

2-3/4
2-3/4
2-3/4
2-3/4
3-3/8
3-3/8
3-3/8

70
70
70
70
86
86
86

8-3/16
8-3/16
8-3/16
8-3/16
8-5/16
8-5/16
8-5/16

208
208
208
208
211
211
211

14
14
14
14
21
21
21

356
356
356
356
533
533
533

IN.       MM

IN.       MM

IN.       MM

62
62
62
62
91
91
91

5
5
5
5
8
8
8

127
127
127
127
203
203
203

58
58
58
58
113
113
113

23
23
23
23
38
38
38

100
100
100
100
165
165
165

71
71
71
71
114
114
114

3/4
1
1-1/4
1-1/2
2
2-1/2
3

M29712

ALLOW 2 IN. (51 MM) CLEARANCE FOR ACTUATOR REMOVAL.

1

B

1

2-7/16
2-7/16
2-7/16
2-7/16
3-5/8
3-5/8
3-5/8

2-5/16
2-5/16
2-5/16
2-5/16
4-7/16
4-7/16
4-7/16

7/8
7/8
7/8
7/8
1-1/2
1-1/2
1-1/2

3-15/16
3-15/16
3-15/16
3-15/16
6-1/2
6-1/2
6-1/2

2-13/16
2-13/16
2-13/16
2-13/16
4-1/2
4-1/2
4-1/2

Содержание V5097A-E

Страница 1: ...uid Power Actuators to provide proof of closure switch and valve seal overtravel interlock V5097D E Valves are for high pressure applications see Table 2 Two valve body types small and large applicable to seven pipe sizes Small body type for 3 4 in 19 mm 1 in 25 mm 1 1 4 in 32 mm 1 1 2 in 38 mm and 2 in 51 mm pipes Large body type for 2 in 51 mm 2 1 2 in 64 mm and 3 in 76 mm pipes Eight pipe adapt...

Страница 2: ...mal manufacturing tolerances therefore an individual unit may not exactly match the specifications listed Also this product is tested and calibrated under closely controlled conditions and some minor differences in performance can be expected if those conditions are changed a Refer to Table 3 or actual pressure ratings of the various combinations of valves and actuators b Valve guide has notches t...

Страница 3: ...dy Valve 8 0 lb 3 64 kg Small Body Pipe Adapters 67 lb 0 3 kg Large Body Pipe Adapters 2 125 lb 97 kg Replacement Parts 133393A Replacement Seal Assembly Includes valve seal bonnet seal and tube of lubricant for Small Body Valves 133392A Replacement Seal Assembly Includes valve seal bonnet seal and tube of lubricant for Large Body Valves For all pipe adapter sizes see Table 4 Replacement Bonnet As...

Страница 4: ...0 86 86 86 8 3 16 8 3 16 8 3 16 8 3 16 8 5 16 8 5 16 8 5 16 208 208 208 208 211 211 211 8 1 4 8 1 4 8 1 4 8 1 4 11 3 4 11 3 4 11 3 4 210 210 210 210 298 298 298 IN MM IN MM IN MM 62 62 62 62 91 91 91 5 5 5 5 8 8 8 127 127 127 127 203 203 203 58 58 58 58 113 113 113 23 23 23 23 38 38 38 100 100 100 100 165 165 165 71 71 71 71 114 114 114 3 4 1 1 1 4 1 1 2 2 2 1 2 3 M11682A ALLOW 2 IN 51 MM CLEARANC...

Страница 5: ...1 2 to 3 13 880 High Pressure Valves V5097D E 3 4 to 2 5 340 40 2700 75 5 25 1 6 62 4 75 5 2 to 3 13 880 45 3 15 1 21 1 4 45 3 6 3 4 171 1 9 32 33 D DIM A DIM B DIM C DIM D DIM E DIM F DIM G DIM H DIM J G E C A H F J OCTAGON OCTAGON 5 127 VALVE SIZE IN IN MM IN MM IN MM IN MM IN MM IN MM IN MM 11 1 8 11 1 8 11 1 8 11 1 8 11 3 4 11 3 4 11 3 4 283 283 283 283 298 298 298 2 3 4 2 3 4 2 3 4 2 3 4 3 3 ...

Страница 6: ...from step 4 for determining the gas valve size in Fig 4 6 Determine the maximum pressure drop across the valve and draw a horizontal line at this pressure in Fig 4 7 Draw a vertical line in Fig 4 at the capacity cfh previously determined Use the corrected capacity for a gas with a specific gravity other than 0 64 8 Use the valve size at the intersection of the horizontal and vertical lines If the ...

Страница 7: ...ed on 0 72 sp gr gas is required What valve capacity based on 0 64 sp gr gas will be required On the vertical scale of Fig 3 find 0 72 specific gravity left side of figure Draw a line horizontally from that point to the right to intersect the curve then move straight down the chart to the bottom scale and read the conversion factor 1 06 in this example Multiply the 2670 cfh by the conversion facto...

Страница 8: ...valve body The retained water is effectively excluded from the valve stem and spring chamber by a functional seal that is incorporated into the NEMA 4 rated actuator When Installing this Product 1 Read these instructions carefully Be sure to carefully fol low Warning information 2 Check the ratings given in the instructions and on the product to make sure the product is suitable for your applicati...

Страница 9: ...ate in the combustion chamber for longer than a few seconds without igniting to prevent an explosive mixture from accumulating WARNING Explosion Hazard Can cause serious injury or death 1 Do not put the system into service until you have satisfactorily completed the following Valve Leak Test all applicable tests described in the Checkout section of the instructions for the flame safeguard control ...

Страница 10: ...uator 1 Turn off the gas supply at the manual shutoff valve located upstream from the valve s being serviced 2 Shut off all electrical power to the valve actuator s 3 Mark and disconnect the wires from the actuator termi nals Remove conduit and disengage the damper link age assembly if applicable 4 Loosen the two set screws from the valve to lift off the actuator 5 If the actuator is to be replace...

Страница 11: ...r mechanical operation CAUTION Be sure to perform a bonnet seal and seat leak check after installation Be sure to read and follow all instructions that come with the actuators valves seal and bonnet kits Valve Bonnet Replacement The entire valve bonnet can be replaced without removing the valve body from the gas line Do not disassemble the valve bonnet assembly because the valve seat is not replac...

Страница 12: ... Honeywell Limited Honeywell Limitée 1985 Douglas Drive North 35 Dynamic Drive Golden Valley MN 55422 Toronto Ontario M1V 4Z9 customer honeywell com V5097A E INDUSTRIAL GAS VALVES U S Registered Trademark 2009 Honeywell International Inc 65 0230 07 M S Rev 08 09 ...

Отзывы: