V4062A,B,D HI-LO-OFF FLUID POWER GAS VALVE ACTUATOR

60-2099—9

2

ORDERING INFORMATION

When purchasing replacement and modernization products from your TRADELINE® wholesaler or distributor, refer to the 

TRADELINE® Catalog or price sheets for complete ordering number.

If you have additional questions, need further information, or would like to comment on our products or services, please write or 

phone:

1.

Your local Home and Building Control Sales Office (check white pages of your phone directory).

2.

Home and Building Control Customer Relations

Honeywell, 1885 Douglas Drive North

Minneapolis, Minnesota 55422-4386 (800) 328-5111

In Canada—Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario M1V 4Z9.

International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, 

Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A.

SPECIFICATIONS

IMPORTANT:

The specifications given in this publication do not 

include normal manufacturing tolerances. Therefore, 

this unit may not exactly match the listed 

specifications. Also, this product is tested and 

calibrated under closely controlled conditions, and 

some minor differences in performance can be 

expected if those conditions are changed.

Models:

V4062A HI-LO-OFF Gas Valve Actuator.

V4062B HI-LO-OFF Gas Valve Actuator, high pressure.

V4062D HI-LO-OFF Gas Valve Actuator with proof-of-closure 

switch. Use with V5055/V5097C,E (double seal) gas 

valves for valve seal overtravel interlock. Do not use 

V4062 with V5034 Valve body.

Electrical Ratings:

Standard V4062A,D Actuators (Table 1): 

60 Hz, 26 second opening. 

50 Hz, 32 second opening.

Table 1. Standard V4062A,D Actuators.

Fast-opening V4062A,D Actuators (Table 2): 

60 Hz, 13 second opening. 

50 Hz, 16 second opening.

Table 2. Fast-opening V4062A,D Actuators.

a

 230V, 50 Hz power supply.

b

 230V, 60 Hz power supply.

Fast-opening V4062B Actuators (Table 3):

60 Hz, 13 second opening.

50 Hz, 16 second opening.

Table 3. Fast-opening V4062B Actuators.

a

 230V, 50 Hz power supply.

b

 230V, 60 Hz power supply.

Pressure Ratings Of Valve-Actuator Combinations:

See Table 4.

Auxiliary Switch And Proof-Of-Closure Switch Ratings:

See Table 5.

Voltage/

Frequency

Opening

Holding

W

VA

W

VA

120V/60 Hz

59.5

129

19.0

28.0

100V/50-60 Hz 53.0/42.7 105/80

20.0/17.2 33/29

200V/50-60 Hz 72.01/52.5 160/110

18.4/16.2 28/24

Voltage/

Frequency

Opening

Holding

W

VA

W

VA

120V/60 Hz

59.5

129

19.0

28.0

220V/50 Hz

84.0

196

17.0

27.0

220V/50 Hz

82.0

180

16.5

26.4

220V-240V; 50-
60 Hz

a

74.5

143.5

13.7

24.8

220V-240V; 50-
60 Hz

b

61.9

112

11.2

20.5

Voltage/Frequency

Opening

Holding

W

VA

W

VA

220V-240V; 50-60 Hz

a

76.5

150.6

13.3

28.8

220V-240V; 50-60 Hz

b

64.4

118.2

11

23.2

Содержание V4062A

Страница 1: ...ch meets code standard insurer requirements Damper shaft models are available with or without spring return shaft extends out both sides and rides in Delrin bushings used with standard damper crank arm part no 7616BR Red OPEN indicator attached to the actuator stem shows when the valve is even slightly open yellow SHUT indicator on the valve stem shows only when the gas valve is fully closed Ambie...

Страница 2: ...e conditions are changed Models V4062A HI LO OFF Gas Valve Actuator V4062B HI LO OFF Gas Valve Actuator high pressure V4062D HI LO OFF Gas Valve Actuator with proof of closure switch Use with V5055 V5097C E double seal gas valves for valve seal overtravel interlock Do not use V4062 with V5034 Valve body Electrical Ratings Standard V4062A D Actuators Table 1 60 Hz 26 second opening 50 Hz 32 second ...

Страница 3: ...3 mm radius for 7616BR Damper Crank Arm ordered separately NOTE Damper shaft drives damper crank arm in one direction only optional return spring is available on damper shaft to turn damper crank arm in opposite direction See Table 6 Table 6 Actuator Torque With and Without Return Spring Ambient Operating Temperature Rating 40 to 150 F 40 to 66 C for 60 Hz models 10 to 158 F 23 to 70 C for 50 Hz a...

Страница 4: ...y switch and or proof of closure switch if used must not exceed the ratings given in the Specifications section 4 When replacing a V6034 Actuator with a V4062 the V5034 Valve body must be changed to a V5055 Valve 5 Do not attempt to use the V4062 Actuator with the V4055 V5034 Adapter Differences in stem travel can prevent correct low fire adjustment Valve Sizea in V5055 V5097 Dim A Dim B Dim C Dim...

Страница 5: ... in the position indicated in Fig 2 Fasten with two screws through the actuator base 4 Insert the proof of closure switch in the position shown in Fig 2 The proof of closure switch mounts against the side of the actuator housing The mounting holes are spaced to allow mounting the switch only in the correct position Fasten with two screws through the actuator base 5 If only one switch is used insta...

Страница 6: ...o control the valve When all wiring connections are complete replace the actuator faceplate CAUTION Equipment Damage Hazard Can cause equipment damage or improper and dangerous operation Label all wires prior to disconnection when servicing valves Wiring errors can cause improper and dangerous operation Fig 4 Typical hookup for V4062 Actuator Fig 5 Connecting Max Flow Limit Switch to the actuator ...

Страница 7: ...rmined low fire setting for the burner being used 5 Tighten the setscrew in the cam 6 Replace the wiring compartment cover Alternate Procedure To adjust the low fire setting after the burner is in operation use the following instructions 1 Remove the wiring compartment cover 2 Check to be sure the low fire adjustment is set at MAX to assure a safe lightoff Low fire adjustment is preset at the fact...

Страница 8: ...UTION Equipment Damage Hazard Unskilled technicians can damage the equipment Only experienced trained flame safeguard control service technicians should service or replace this control Service The actuator is not field repairable except for replacing the auxiliary switch or valve closed indication switch See Installation section for procedure Do not disassemble the valve actuator If the actuator s...

Отзывы: