Honeywell UV100A Скачать руководство пользователя страница 1

69-1381-4

UV100A Ultraviolet System

OWNER’S GUIDE

Содержание UV100A

Страница 1: ...69 1381 4 UV100A Ultraviolet System OWNER S GUIDE ...

Страница 2: ...traviolet Air Treatment System kills a high percentage of airborne germs circulating through your forced air heating and cooling system Individual results depend on careful installation and maintenance and on the actual amount of time your system fan operates See Fig 1 Fig 1 Typical Air Treatment System installations M22858 WARN ING A VERT ISSEM ENT Nocifs pour la peau nue et les Veuill ez lire et...

Страница 3: ...ons You can capture and minimize micro organisms passing through your forced air system when you combine your UV System with a high efficiency air filtration system like an electronic air cleaner Talk to your installer about adding an electronic air cleaner to complement your UV System and provide added protection for you and your family M22860 WARN ING A VERT ISSEM ENT Nocifs pour la peau nue et ...

Страница 4: ...allows ultraviolet light to be seen after installation Do not attempt to bypass duct mount switch Do not attempt to open housing unit is sealed to prevent ultraviolet light exposure CAUTION Personal Injury Hazard Power supply can cause electrical shock Disconnect power supply before cleaning or replacing ultraviolet bulb s Do not open base unit or lamp handle there are no user serviceable componen...

Страница 5: ...ulb s Do not place your used bulb s in the trash Dispose of properly Broken Bulb Cleanup Do not use a household vacuum Sweep debris phosphor glass into a plastic bag and dispose of properly Contact your local waste management authority for instructions regarding recycling and the proper disposal of old bulb s ...

Страница 6: ...sealed unit the ultraviolet lamp does not illuminate unless the base is mounted on your forced air system duct It is recommended that every month you verify that your ultraviolet lamp is operating View the bulb only through the lamp light indicator on the lamp handle See Fig 3 Do not attempt to look into the duct at the illuminated bulb s Fig 3 Lamp light indicator M22840 LAMP LIGHT INDICATOR ...

Страница 7: ...d as routine maintenance four times a year or every three months Use the UV Bulb Cleaning Reminder Schedule Fig 4 to help establish and track your regular cleaning schedule Fig 4 UV bulb cleaning reminder schedule To clean your bulb s 1 Disconnect the power to your heating and cooling system 2 Unplug or turn off power to your UV System and allow the bulb s to cool for at least 15 minutes YEAR UV B...

Страница 8: ...ss using a soft cloth dampened with glass cleaner If you touch the lamp glass with your hands be sure to clean the area of any oils left from bare hands See Fig 6 Fig 6 Clean glass with soft cloth 5 Also wipe away any dust that may have collected between the lamp light indicator on the base and the black bulb base See Fig 7 Fig 7 Wipe lamp light indicator base M22842 M22844 LAMP LIGHT INDICATOR BA...

Страница 9: ...n Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 8 Fig 8 Position bulb for insertion back into the lamp base 8 Rotate the lamp handle clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 9 Fig 9 Snap bulb into place M22848 M22850 ...

Страница 10: ...acement bulb for your unit See Table 1 2 Disconnect the power to your heating and cooling system 3 Unplug or turn off power to your UV System and allow lamps to cool for at least 15 minutes 4 Rotate the lamp handle counterclockwise and gently pull the lamp handle to remove the bulb See Fig 5 Table 1 Select a Replacement Bulb Handle Assembly or Replacement Bulb Unit Description Replacement Bulb Han...

Страница 11: ...handle 7 Insert the bulb into the base with the lamp light indicator at the eleven o clock position Continue pushing and gently rotating counterclockwise until the lamp handle inserts fully into the base See Fig 8 8 Rotate the lamp clockwise until it snaps into place with the lamp light indicator aligned with the raised button on the unit cover See Fig 9 9 Reconnect power to your UV System 10 Veri...

Страница 12: ...t is shown by Honeywell that the defect or malfunction was caused by damage which occurred while the product was in the possession of a consumer Honeywell s sole responsibility shall be to repair or replace the product within the terms stated above HONEYWELL SHALL NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES RESULTING DIRECTLY OR INDIRECTLY FRO...

Отзывы: