background image

1

69-0838

a

Capacity based on 1000 Btu/feet

3

, 0.64 specific gravity natural gas at 1 inch wc pressure drop [37.3 MJ/meter

3

, 0.64 specific

gravity natural gas at 0.25 kPa pressure drop].

Size

(Inlet x Outlet)

Capacity (at 1 inch
wc pressure drop)

a

Minimum

Regulated Capacity

Maximum

Regulated Capacity

1/2 x 1/2

240 feet

3

/hour

[6.8 meter

3

/hour]

30 feet

3

/hour

[0.8 meter

3

/hour]

340 feet

3

/hour

[9.6 meter

3

/hour]

1/2 x 3/4

270 feet

3

/hour

[7.6 meter

3

/hour]

30 feet

3

/hour

[0.8 meter

3

/hour]

370 feet

3

/hour

[10.5 meter

3

/hour]

3/4 x 3/4

300 feet

3

/hour

[8.5 meter

3

/hour]

30 feet

3

/hour

0.8 meter

3

/hour]

415 feet

3

/hour

[11.8 meter

3s

/hour]

J.D.  •  4-94  •  ©Honeywell Inc. 1994  •  Form Number 69-0838

VR4304

Intermittent Pilot

Combination Gas Control

Application

These intermittent pilot gas controls are used in gas-fired

appliances with capacities up to 300 feet

3

/hour at 1 inch

wc pressure drop [8.5 meters

3

/hour at 0.25 kPa] for natural

gas. They include a manual valve, two automatic operators,
a pressure regulator, pilot adjustment and a conduit cover.
The ambient temperature range for the standard-opening
TRADELINE

®

 model (VR4304M) is -40

°

 to +175

°

  F

[-40

°

 to +79

°

 C].

BODY PATTERN: Straight-through.
INLET X OUTLET SIZES AVAILABLE: 1/2 x 3/4 inch

and 3/4 x 3/4 inch.

This TRADELINE gas control comes with two 3/4 to

1/2 inch NPT bushings and one 1/2 to 3/8 inch NPT
bushing.

ADAPTERS: Adapters available for 1/2 and 3/4 inch

straight and angle connections. Refer to Table 2.

ELECTRICAL RATINGS:

Voltage and Frequency: 120 Vac, 60 Hz.
Current Draw: 0.14A.

TRADELINE

®

CAPACITY:

Use conversion factors in Table 1 to convert capacities

for other gases.

TABLE 1—GAS CAPACITY CONVERSION FACTORS.

Gas

Specific
Gravity

Multiply Listed

Capacity By

Manufactured

0.60

0.516

Mixed

0.70

0.765

Propane

1.53

1.62

TABLE 2—ADAPTER (FLANGE) PART NUMBERS.

Part Number

Inlet/

Outlet

Pipe Size

Flange

Type

Without

Hex

Wrench

With

Hex

Wrench

1/2 inch NPT

Straight

393690-6

393690-16

Elbow

393690-3

393690-13

3/4 inch NPT

Straight

393690-4

393690-14

Elbow

393690-5

393690-15

NOTE: Flange Kits include one flange with attached O-ring

and four mounting screws.

APPROVALS:

American Gas Association design certificate:

L2025007.

Canadian Gas Association design certificate:

L2025007.

Australian Gas Association design certificate:

Applied for.

Delta C.

Содержание TRADELINE VR4304

Страница 1: ...emperature range for the standard opening TRADELINE model VR4304M is 40 to 175 F 40 to 79 C BODY PATTERN Straight through INLET X OUTLET SIZES AVAILABLE 1 2 x 3 4 inch and 3 4 x 3 4 inch This TRADELINE gas control comes with two 3 4 to 1 2 inch NPT bushings and one 1 2 to 3 8 inch NPT bushing ADAPTERS Adapters available for 1 2 and 3 4 inch straight and angle connections Refer to Table 2 ELECTRICA...

Страница 2: ...therwise use the following instructions CONVERTING BETWEEN NATURAL AND LP GAS WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE SEVERE INJURY OR DEATH Do not attempt to use a gas control set for natural gas on LP gas or a gas control set for LP gas on natural gas Convert standard opening gas controls from natural gas to LP gas with the conversion kit included with this TRADELINE gas contr...

Страница 3: ... follow these guidelines Locate gas control in a well ventilated area Mount gas control high enough above the cabinet bottom to avoid exposure to flooding or splashing water Make sure the ambient temperature does not exceed the ambient temperature ratings for each component Cover gas control when the appliance is cleaned with water steam or chemicals or to avoid dust and grease accumulation Avoid ...

Страница 4: ...h wrench Do not overtighten Refer to Fig 6 5 Connect other end of tubing to pilot burner according to pilot burner manufacturer instructions WIRING Follow the wiring instructions furnished by the appli ance manufacturer if available or use the following general instructions provided below Where these instructions dif fer from the appliance manufacturer follow the appliance manufacturer instruction...

Страница 5: ...ate the gas control knob counterclockwise to ON TURN ON MAIN BURNER Follow instructions provided by appliance manufac turer or turn up thermostat to call for heat PERFORM GAS LEAK TEST WARNING FIRE OR EXPLOSION HAZARD CAN CAUSE PROPERTY DAMAGE SEVERE INJURY OR DEATH Check for gas leaks with a rich soap and water solution anytime work is done on a gas control GAS LEAK TEST 1 Paint all pipe connecti...

Страница 6: ...ow rate by using the meter clocking method or check the gas pressure using a manometer connected to the gas control outlet pressure tap Refer to Fig 4 3 If necessary adjust the pressure regulator to match the appliance rating Refer to Table 4 or 5 for the factory set nominal outlet pressures and adjustment setting ranges a Removethepressureregulatoradjustmentcapscrew b Using a screwdriver turn the...

Страница 7: ...ature Maintenancefrequencymustbedetermined individually for each application Some considerations are Cyclingfrequency Appliancesthatmaycycle100 000 times annually should be checked monthly Intermittent use Appliances that are used seasonally should be checked before shutdown and again before the next use Consequence of unexpected shutdown Where the cost of an unexpected shutdown would be high the ...

Страница 8: ...nstructions pro vided by the manufacturer of your heating appliance The information below will be of assistance in a typical gas control application but the specific con trols used and the procedures outlined by the manu facturer or your appliance may differ and require special instructions TO TURN ON THE APPLICANCE STOP READ THE WARNINGS ABOVE The pilot flame is lit automatically Do not attempt t...

Отзывы: