1126800
SmartPAC 2 with WPC Integration
Page 380
Chapter 6
SmartPAC 2 Run Mode
Operating the Press in BAR Mode
DANGER
!
injury when using Bar mode
•
Keep all personnel away from the press while it is being barred
•
Use a spring-loaded turnover bar when you bar the press.
Failure to comply with these instructions will result in death or serious injury.
You can operate in Bar Mode if you have the Bar control option. To operate the press in the
Bar mode, perform these steps. Set the stroke select switch to INCH. Then set the mode
select switch to TWO HAND. Turn off the press's main motor.
Turn the select switch on the Bar control enclosure to ON, and then wait for the press
flywheel to stop turning. Now press the OPERATE button, and bar the press using a spring-
loaded bar.
Make sure you do not rotate the flywheel/crank too quickly (more than an equivalent of 6
SPM), or WPC will stop the ram.
If this happens, error code "F26" will appear on the digital
readout. Press the RESET key to continue barring the press.
Multiple Operator Stations
DANGER
!
HAZARDS EXPOSED BY NON-WORKING OPERATOR STATION
Safeguard the point of operation exposed by the non-working operator station when using
multiple operator stations. This exposed area near a disabled operator station must be
properly guarded.
•
Ensure that guarding is properly installed to prevent access to the machine over, under or
around any guarding device.
Failure to comply with these instructions will result in death or serious injury.
You can have an unlimited number of operator stations as part of your WPC system.
However, up to two operator stations are standard. More than two operator stations need to
be connected to WPC via a Dual Operator Selection Control (Wintriss part no. 4152100).
See Chapter 2 to install and connect these components to your WPC.
When you have more than one operator station connected to WPC, the palm time allotment
changes from 0.5 second to 5 seconds. This means that all the palm buttons on every station
must be actuated within a 5-second time frame. If the first operator depresses his palm
button, then all other palm buttons in the series must be actuated within 5 seconds. If not, the
allowable "palm time" expires, and you must depress the palm button again.
Содержание SmartPAC 2
Страница 192: ...1126800 SmartPAC 2 with WPC Integration Page 170 Chapter 2 Installing SmartPAC 2 and WPC ...
Страница 222: ...1126800 SmartPAC 2 with WPC Integration Page 200 Chapter 3 SmartPAC 2 Keyboard Displays and Operating Modes ...
Страница 294: ...1126800 SmartPAC 2 with WPC Integration Page 272 Chapter 4 SmartPAC 2 Initialization Mode ...
Страница 342: ...1126800 SmartPAC 2 with WPC Integration page 320 Chapter 5 SmartPAC 2 Program Mode ...
Страница 404: ...1126800 SmartPAC 2 with WPC Integration Page 382 Chapter 6 SmartPAC 2 Run Mode ...
Страница 448: ...1126800 SmartPAC 2 with WPC Integration Page 426 Chapter 7 SmartPAC 2 Fault Messages ...
Страница 476: ...1126800 SmartPAC 2 with WPC Integration page 454 Appendix C Updating SmartPAC 2 Firmware ...
Страница 478: ...1126800 SmartPAC 2 with WPC Integration page 456 Appendix D SmartView Remote Viewing and E mail Setup ...
Страница 480: ...1126800 SmartPAC 2 with WPC Integration page 458 Appendix E Upgrade from Original SmartPAC to SmartPAC 2 ...
Страница 482: ...1126800 SmartPAC 2 with WPC Integration page 460 Appendix F Replacing SmartPAC 2 PC Board ...
Страница 492: ...1126800 SmartPAC 2 with WPC Integration page 470 Glossary ...