The SiXCT is a wireless door / window sensor
intended for use with Honeywell controls that
support SiX™ series devices.
Open the SiXCT
•
Firmly slide the top and bottom housings in
opposite directions and pull them apart to open
the device.
Mounting
The SiXCT can be mounted with several options:
•
Installation with magnet: Make gap is 0.75";
Break gap is 1.30".
•
Optional Wiring for Service loops:
a) surface wiring
b) concealed wiring
NOTE
: Wiring limit is 3ft.
NOTE
: After enrolling and before mounting the
device permanently, conduct Go/No Go tests (see
controller’s instructions) to verify adequate signal
strength. Adjust the device location and orientation
as necessary.